Install the DIMM.
7.
Install the air baffle (on page 30).
8.
Install the access panel (on page 25).
9.
Do one of the following:
10.
Slide the server into the rack.
o
Install the server into the rack
o
Power up the server (on page 20).
11.
After installing the DIMMs, use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities
System
Utilities" on page 113) to configure the memory protection mode.

PCI riser cage assembly options

The server supports two PCI riser cage assembly options. Both PCI riser cage assembly options can be
installed in either the primary or the secondary PCIe riser location. For instructions on how to install these
options, see "PCI riser cage assembly options (on page 86)." A second processor is required to support
installation in the secondary PCIe riser location. For more information on the riser board slot specifications,
see "PCIe riser board slot definitions (on page 12)."
For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP website (http://www.hp.com/go/qs).
To install the component:
Power down the server (on page 20).
1.
Remove all power:
2.
Disconnect each power cord from the power source.
a.
Disconnect each power cord from the server.
b.
Do one of the following:
3.
Extend the server from the rack (on page 20).
o
Remove the server from the rack (on page 22).
o
("Installing the server into the
rack" on page 36).
Hardware options installation 86