– Further timing cover attachment and en-
gine assembly procedures are as descri-
bed for removal, but working in the re-
verse order.
Note:
When renewing the breather valve, secure
the new valve housing in the insert (105/3)
with sealant E and then seal all around
with sealant H.
If the insert is renewed, use sealant C for
bonding in.
The hose spigot opening in the air intake
pipe must face toward the intake port of
cylinder 1.
The position of the opening can be varied
by inserting or removing spacing washers
(only on engines with crankcase breather
in timing cover).
3
L / M . . 09.96