Input Voltage - GRAUPNER ULTRAMAT AC/DC EQ Operating Instructions Manual

Table of Contents

Advertisement

- Operating mode
CHG
Charge mode
C->D
Charge to Discharge
BLC
When a battery is connected to balancer connector
- Battery type
ㆍNC : NiCd, NiMH
ㆍLF : LiFe/A123
- If you press ENTER button then the charge or discharge is terminated.
- If you press and hold DATA VIEW button for more than 3 sec, you may check the pro-
gramming setup status. Press DEC/INC buttons to go to other mode and press DATA
VIEW button again to get back to the previous display. You may get the all information
such as input/output voltage, battery voltage/ capacity, the voltage of the highest/ lowest
cell, the voltage of each cell, the average voltage, the peak voltage, the balancer volt-
age, the peak temperature.
INPUT
=
OUTPUT
=
LCB-[ 01 ] =
LCB-AVG =
LCB-MAX =
LCB-MIN =
0.00
0.00
0.00
0.00
◎ ERROR MESSAGES
INPUT
BATTERY
VOLTAGE
NO
BATTERY
OUTPUT
BATTERY
REVERSE
POLARITY
16
ULTRAMAT AC/DC EQ
ㆍLP : LiPo
ㆍPB : Pb
12.08V
ChgCAPA =
8.08V
DchCAPA =
When balancer connector is ported, this display is ap-
0.000V
peared. Press ENTER button then the value [01] blinks,
0.000V
press DEC/INC buttons to check the voltage of each cell.
0.000V
It is the other display when balancer connector is ported
0.000V
you may check the max/min voltage
0.00V
0.00V
When input voltage is below 11.0V or exceeds 15V.
ERROR
When a battery is not connected to the charger's output
When a battery is connected to the output in reverse
DCH
Discharge mode
D->C
Discharge to Charge
ㆍLI : LiIon
0mAh
0mAh
CHG PEAK=
DCHG AVR=
0.00V
0.00V

Advertisement

Table of Contents
loading