Datalogic Matrix 300 Reference Manual page 87

Hide thumbs Also See for Matrix 300:
Table of Contents

Advertisement

TYPICAL LAYOUTS
The same configuration can be made to a Host using a TCP/IP Ethernet interface. In this
case the Master is connected to a CBX500 with BM200/210 Host Interface Module installed.
The TCP/IP Ethernet, auxiliary, and ID-NET™ interfaces are connected as shown in the
figure below.
Power
CBX500
Master
3
Figure 68 – ID-NET™ M/S Multidata Layout with BM200/210 TCP/IP Ethernet Interface to Host
NOTE: The auxiliary serial interface of the slave readers can be used in
Local Echo communication mode to control any single reader (visualize
collected data) or to configure it using the VisiSet™ utility.
The ID-NET™ termination resistor switches must be set to ON only in the first
and last CBX connection box.
4
1
Slave#1
Host
BM2x0 TCP/IP Ethernet Interface
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for One Shot or Phase Mode)
ID-NET™ (up to 32 devices, max network extension of 1000 m)
Slave#n
2
5
75