SOFTWARE CONFIGURATION
Figure 85 - Example Extending DOF Using Alternative Acquisition Group
Since many factors and parameters contribute to maximizing the reading process, it is
suggested to use the VisiSet™ Standard Setup Wizard to set the different acquisitions
settings.
Multi Image Acquisition Settings Procedure using Standard Setup Wizard:
1. Using the Standard Setup Wizard set the first acquisition setting (default) for the 195 mm
Reading Distance. Save the setting to Permanent Memory.
2. Through the Calibration Tool (Interactive Mode):
a. Set Calibration>Image Acquisition Setting 1 - Status to Disabled
b. Set Calibration>Image Acquisition Setting 2 - Status to Enabled
c. Set LEDs And Keypad>Autolearning Setup>Image Acquisition Setting to 2
d. Close the Calibration Tool
3. Using the Standard Setup Wizard set the second acquisition setting for the 300 mm
Reading Distance. Save the setting to Permanent Memory.
4.
Get the Configuration from the Device Memory (do not use Interactive mode):
a. Set Operating Mode>Alternative Acquisition Group Select to Input 2 Leading Edge
b. Set Calibration>Image Acquisition Setting 1 > Status to Enabled
c. Set Calibration>Image Acquisition Setting 1 > Acquisition Group to Alternative
d. Set Calibration>Image Acquisition Setting 2 > Status to Enabled
e. Set Calibration>Image Acquisition Setting 2 > Acquisition Group to Standard
f. Send Configuration to Permanent Memory
5. Verify that the reader decodes at both distances with the Calibration Tool.
Proximity Sensor
on Input 2
Ext. Trigger
7
121