Datalogic Matrix 300 Reference Manual page 14

Hide thumbs Also See for Matrix 300:
Table of Contents

Advertisement

1
CBX100/CBX500 Pinout for Matrix 300™
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this
pinout when the Matrix 300™ reader is connected by means of the CBX100/CBX500:
Input Power
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Power Source – External Trigger
+V
I1A
External Trigger A
I1B
External Trigger B
Power Reference – External Trigger
-V
Power Source – Inputs
+V
I2A
Input 2 A
I2B
Input 2 B
Power Reference – Inputs
-V
Shield
Network Cable Shield
* Do not leave floating, see par. 4.2.2 for connection details.
CAUTION: Do not connect GND, SGND and REF to different (external)
ground references. GND, SGND and REF are internally connected through
filtering circuitry which can be permanently damaged if subjected to voltage
drops over 0.8 Vdc.
2
CBX100/500 Terminal Block Connectors
Inputs
(polarity insensitive)
(polarity insensitive)
(polarity insensitive)
(polarity insensitive)
Shield
Main Interface
RS232
TX
RTS
RX
CTS
SGND
MATRIX 300™ REFERENCE MANUAL
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
O3A
Output 3 (CBX500 only)
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
ID-NET™
REF
Network Reference
ID-NET™ network +
ID+
ID-NET™ network -
ID-
RS485/422 Full-Duplex
TX+
TX-
*RX+
*RX-
SGND

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents