19 – Working with measurement tools and isotherms
Setting up a
Follow this procedure to set up an isotherm color that is displayed when the camera
humidity isotherm
detects an area where there may be a risk of humidity in a building structure:
Setting up an
Follow this procedure to set up an isotherm color that is displayed when the camera
insulation
detects what may be an insulation deficiency in a wall:
isotherm
62
netzerotools.com
1
Push the Menu/Back button.
2
On the main menu, go to the Tools button
3
On the Tools menu, select Add isotherm
4
Select Humidity.
5
Use the joystick to set the following parameters:
Rel. humidity limit: The critical limit of relative humidity that you want to
detect in a building structure. For example, mold will grow in areas where
the relative humidity is less than 100%, and you may want to find such
areas.
Rel. hum.: The current relative humidity at the inspection site.
Atm. temp.: The current atmospheric temperature at the inspection site.
1
Push the Menu/Back button.
2
On the main menu, go to the Tools button
3
On the Tools menu, select Add isotherm
4
Select Insulation.
5
Use the joystick to set the following parameters:
Inside temp.: The temperature inside the building you are inspecting.
Outside temp.: The temperature outside the building you are inspecting.
Thermal index: The accepted energy loss through the wall. Different
building codes recommend different values, but typical values are 60–80
for new buildings. Refer to your national building code for recommenda-
tions.
netzerotools.com
and push the joystick.
and push the joystick.
and push the joystick.
and push the joystick.