2. ADJUSTMENT

2-1. Table for Servicing Tools
Ref. No.
Name
J-1
Pattern box
J-2
Calibration software
J-3
Chroma meter
J-4
Spare lump (pattern box)
J-5
Collimator
J-6
Spare lump (collimator)
1. Calibration software
Download the calibration software and the firmware from the
following URL.
http://www.overseas.sanyo.com/dcamera_service/
Place the DscCalDi.exe file, camapi32.dll file and
QrCodeInfo.dll file together into a folder of your choice.
2. Pattern box
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure. It is used after adjusting the
chroma meter (VJ8-0192) adjust color temperature to 3100
± 20 K and luminosity to 900 ± 20 cd/m
dling the lump and its circumference are high temperature
during use and after power off for a while.
2-2. Setup
1. System requirements
Windows 2000 or XP or Vista
IBM® -compatible PC with pentium processor
USB port
2. Video monitor
Connect the video output to a video monitor with an input
impedance of 75 ohms.
2-3. Adjustment Items and Order
1. Timer Quartz Adjustment
2. AWB Adjustment
3. CMOS White Point Defect Detect Adjustment
4. CMOS Black Point And White Point Defect Detect Adjust-
ment In Lighted
5. Focus Assistance Drive Adjustment
Note: If the lens, CMOS and board and changing the part, it
is necessary to adjust again. Item 1-5 adjustments should be
carried out in sequence.
Part code
Number
1
VJ8-0190
1
1
VJ8-0192
1
VJ8-0191
1
VJ8-0260
1
VJ8-0282
2
. Be careful of han-
-
9
2-4. Connecting the camera to the computer
1. Connect the camera's USB terminal to the computer'
USB connector.
2. It turns on power while pushing the FAR button and the
SET button of the operation panel.
3. Double-click on the DscCalDi.exe.
4. L5DE2 is selected with Model Code.
5. PAL (VDC-HD3500P) or NTSC (VDC-HD3500) is
selected with Video Mode.
2-4-1. Computer screen during adjustment
Calibration
Upload
AWB
Firmware
Focus
QrCode
UV Matrix
Cal Mode
Initialize
OK
EVF
VCO
Cal Data
LCD Type
OK
USB storage
Get
VID
Set
Serial
PID
Set
Backrush pulse :
Get
2-4-2. Operation buttons
1: NEAR button
2: FAR button
3: SET button
4: REVERSE button
5: RESET button
-
LCD
R Bright
B Bright
VCOMDC
RGB Offset
Gain
VCOMPP
Tint
Phase
H AFC
Test
Setting
Language
Set
Video Mode
Set
Rev.
Set
Factory Code
Set
Model_Code
3 2 1
3 2 1
4 4
5