7.6 X13

X13
External Position Sensor Differential Hall Switches
case
DSUB-15 (f)
Position Encoder Inputs ( RS422):
Max. counting frequency: 25 Mcounts/s with quadrature decoding, 40ns edge separation
Differential Hall Switch Inputs (RS422):
Input Frequency: <1kHz
Enc. Alarm In:
5V / 1mA
Sensor Supply:
5VDC max 100mA

7.7 X17 - X18

X17 - X18
RealTime Ethernet 10/100 Mbit/s
X17 RT ETH In
X18 RT ETH Out
RJ-45
NTI AG / LinMot
®
Preliminary
ABZ with Hall Switches
1
+5V DC
9
A+
2
A-
10
B+
3
B-
11
Z+
4
Z-
12
Encoder Alarm
5
GND
13
U+
6
U-
14
V+
7
V-
15
W+
8
W-
Shield