C1200 Installation Guide
8 Error Codes
Error
Warn
Off
Warning
On
● ~2Hz
0..15 x
Error Code
High Nibble
● ~2Hz
● ~2Hz
0..15 x
Error Code
High Nibble
● ~4Hz
● ~2Hz
0..15 x
Error Code
High Nibble
● ~0.5Hz
● ~0.5Hz
The meaning of the error codes can be found in the
Usermanual_MotionCtrl_Software_SG5 and the user manual of the installed
interface software. These documents are provided together with LinMot-Talk
configuration software and can be downloaded from www.linmot.com.
Page 16/22
Error Codes
EN
Operation
Normal Operation:
Enabled
Warnings and operation enabled are displayed.
● ~2Hz
Error:
0..15 x
The error code is shown by a blink code with "WARN" and "EN".
Error Code
The error byte is divided into low and high nibble (= 4 bit).
Low Nibble
"WARN" and "EN" are blinking together.
The error can be acknowledged.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
● ~2Hz
Fatal Error:
0..15 x
The error code is shown by a blink code with "WARN" and "EN".
Error Code
The error byte is divided into low and high nibble.
Low Nibble
"WARN" and "EN" are blinking together.
Fatal errors can only be acknowledged by a reset or power cycle.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
● ~2Hz
System Error:
0..15 x
Please reinstall firmware or contact support.
Error Code
Low Nibble
On
Signal Supply 24V too low:
The error and warn LEDs blink alternating if the signal supply +24V (X4.2) is
less than 18VDC.
www.LinMot.com
Preliminary
Description
®
NTI AG / LinMot