C1200 Installation Guide
7.8 X19
X19
System
RJ-45
Use Adapter cable AC01-RJ45/Df-2.5-RS1 (Art.-No. 0150-2143) for Configuration over RS232.
7.9 X33
X33
Spring cage connector
7.10
S1 - S2
S1 - S2
Address Selectors
S1 (5..8)
S2 (1..4)
The use of these switches depends on the type of fieldbus which is used. Please see the corresponding
manual for further information.
Page 14/22
1
(Do not connect)
2
(Do not connect)
3
RS232 Rx
4
GND
5
GND
6
RS232 Tx
7
(Do not connect)
8
(Do not connect)
case
Shield
Safety Relays (only with the -1S option)
4 / 8
Ksr +
3 / 7
Ksr -
2 / 6
Ksr f+
1 / 5
Ksr f-
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm
- Stripping length: 10mm
- Never connect the safety relays to the logic supply of the drive!
Bus ID High (0 ... F). Bit 5 is the LSB, bit 8 the MSB.
Bus ID Low (0 ... F). Bit 1 is the LSB, bit 4 the MSB.
www.LinMot.com
Preliminary
Safety Relay 1 / 2 Input positive
Safety Relay 1 / 2 Input negative
Safety Relay 1 / 2 feedback positive
Safety Relay 1 / 2 feedback negative
2
®
NTI AG / LinMot