Safety Wiring - LinMot C1200 Installation Manual

Servo drives
Hide thumbs Also See for C1200:
Table of Contents

Advertisement

9 Safety Wiring

The C1200 drives with the -1S option have internal safety functions:
Two Safety relays Ksr in series, which support the supply voltage for the motor
drivers. There are also two feedback contacts for each relay.
To enable the -1S drives both relays have to be switched on.
Minimal wiring:
- Connect X33.8 and X33.4 to 24VDC (from safety)
- Connect X33.7 and X33.3 to GND (from safety)
Attention: Never connect X33.8 and X33.4 to the logic supply of X4!
If an overvoltage protection is needed, it must be provided externally and
sized according the safety circuit of the machine!
Attention: The drop out time of the relays is depending on the external circuitry!
Safety Relay Ksr
Nominal voltage
Min. pick-up voltage at 20°C
Drop-out voltage at 20°C
Drop-out time (no protection circuit)
Coil resistance at 20°C
Type
Contact lifetime
Manufacturer and type
Drive Classification according EN ISO 13849-1 (safety of machinery) (preliminary)
Category
Performance Level
Diagnostic Coverage
Mean Time to hazardous failure of one channel
NTI AG / LinMot
®
Preliminary
www.LinMot.com
C1200 Installation Guide
24 VDC
≤ 16.8V
≥ 2.4 V
Typ. 3ms
2'100 Ω ± 10%
EN 50205, type A
> 10'000'000
Elesta relays / SIS112 24VDC
cat = 3
PL = d
DC = high
MTTFd = high
Page 17/22