Download Print this page

Jackson MSC 10AB-N70 Installation And Operation Manual page 12

Advertisement

All electrical ratings provided in this manual are for reference only. Always refer to the machine data plate
to get the exact electrical information for your machine. All electrical work performed on machines
should be done in accordance with applicable local, state, territorial and national codes. Work should
only be performed by qualified electricians and authorized service agents. A list of authorized Service Agen-
cies is located in the back of this manual.
Note that all electrical wiring used in the dish-machine must be rated, at a minimum, for 100C (212F).
Furthermore, use copper conductors only.
Where applicable, heating element amperage draws have been adjusted for the assumed input voltage. Jack-
son assumes incoming voltages will be either 208, 230 or 460 volts. Some of the heating elements used in
the machines are actually rated for other voltages, such as 240 or 480 volts. Always verify the amperage
draw of the machine in operation when sizing circuit protection.
The electrical configurations of the machines are as follows:
Available Electrical Characteristics:
440 volt, 60 Hz, Three phase
10AB-N70 with 13.4 kW Rinse Heater
Volts
Phase
440
3
Technical Manual (07610-003-97-40)
Notes Regarding Electrical Requirements
Wash
Drive
Freq
Motor
Motor
Amps
Amps
60
.8 A
Page Created: 09-10-2012
Rinse
Heater
Amps
N/A
20.8
7
FLA
MCA
21.6A
22.8A
MOP
23.8A

Advertisement