Checking The Auger Gearbox Oil Level - Toro Power Max 38801 Operator's Manual

Heavy duty 928/1028 ohxe
Table of Contents

Advertisement

Figure 47
3. With the auger/impeller lever disengaged, ensure that
the gap between the auger clutch assembly and the tab
is 1/16 inch (1.5 mm) (Figure 48).
Figure 48
1. Tab
2. 1/16 inch (1.5 mm)
4. If the auger/impeller cable is not properly adjusted, do
the following steps:
5. Loosen the jam nut (Figure 49).
Figure 49
1. Jam nut
2. Turnbuckle
6. Loosen or tighten the turnbuckle that adjusts the
tension on the cable (Figure 49).
7. Adjust the turnbuckle until you obtain the proper gap.
8. Tighten the jam nut.
9. Insert the 2 screws you previously removed on the belt
cover.
10. If the auger/impeller cable is properly adjusted but
a problem remains, contact an Authorized Service
Dealer.
Checking the Auger Gearbox
Oil Level
Service Interval: Yearly—Check the auger gearbox oil and
add oil if necessary.
1. Move the machine to a level surface.
2. Clean the area around the pipe plug (Figure 50).
1. Pipe plug
3. Remove the pipe plug from the gearbox.
4. Check the oil level in the gearbox. The oil should be at
the point of overflowing at the filler opening.
5. If the oil level is low, add GL-5 or GL-6, SAE 85-95
EP gear oil lubricant to the gearbox until the point of
overflow.
Note: Do not use synthetic oil.
6. Install the pipe plug in the gearbox.
23