Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Remove the 2 screws that are holding the belt
cover in place
(Figure
2.
Remove the belt cover
Figure 30
3.
With the auger/impeller lever disengaged,
ensure that the gap between the auger clutch
arm and the frame of the machine is 1.5 mm
(1/16 inch) as shown in
Figure 31
1. 1.5 mm (1/16 inch)
2. Frame
4.
If the auger/impeller cable is not properly
adjusted, do the following steps:
5.
Loosen the jam nut
30).
(Figure
30).
Figure
31.
3. Auger clutch arm
(Figure
32).
1. Jam nut
6.
Loosen or tighten the turnbuckle that adjusts the
tension on the cable
7.
Adjust the turnbuckle until you obtain the proper
gap.
8.
Tighten the jam nut.
9.
Insert the 2 screws that you previously removed
on the belt cover.
10.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.
g323250
Checking the
Auger-Gearbox-Oil Level
Service Interval: Yearly—Check the auger-gearbox
1.
Move the machine to a level surface.
2.
Clean the area around the pipe plug and remove
the pipe plug from the gearbox
Note:
If needed, use pliers to assist in removing
the pipe plug.
g260108
19
Figure 32
2. Turnbuckle
(Figure
32).
oil and add oil if necessary.
(Figure
g322960
33).