Checking and Adjusting the
Auger/Impeller Cable
Service Interval: After the first 2 hours—Inspect the
auger/impeller cable and adjust it if
necessary.
Yearly—Inspect the auger/impeller cable and
adjust or replace it if necessary.
1.
Loosen the jam nut.
2.
Engage the auger/impeller lever and hold it in
place
(Figure
31).
Figure 31
3.
Loosen or tighten the turnbuckle to adjust the
spring length to 7 cm (2-3/4 inches) as shown
in
Figure
32.
Figure 32
1. Jam nut
2. Turnbuckle
4.
Tighten the jam nut
there is slight tension on the cable.
5.
If the auger/impeller cable is properly adjusted
but a problem remains, contact an Authorized
Service Dealer.
3. Spring
4. 7 cm (2-3/4 inches)
(Figure
32), ensuring that
Checking the
Auger-Gearbox-Oil Level
Service Interval: Yearly—Check the auger-gearbox
1.
Move the machine to a level surface.
2.
Clean the area around the pipe plug
g322975
1. Pipe plug
3.
Remove the pipe plug from the gearbox.
4.
Check the oil level in the gearbox. The oil should
be 9.5 mm (3/8 inch) below the filler opening.
5.
If the oil level is low, add GL-5 or GL-6, SAE
80-90 EP gear oil lubricant to the gearbox until
the oil level is 9.5 mm (3/8 inch) below the filler
opening.
Note:
Do not use synthetic oil.
6.
Install the pipe plug in the gearbox.
g031000
20
oil and add oil if necessary.
Figure 33
(Figure
33).
g016782