4.1 RAV-133TU-PE
No.
PARTS NAME
1
Indoor unit fan motor (x2)
Running capacitor for
2
indoor fan motor (x2)
3
Transformer (Indoor unit)
4
Stepper motor (x2)
5
Relay
6
Drain pump
7
Float switch
Sensor for room
8
temperature
Indoor unit sensor for
9
heat-
exchanger
temperature.
4.2. RAV-163TU-PE
No.
PARTS NAME
1
Indoor unit fan motor (x2)
Running capacitor for indoor
2
fan motor (x2)
3
Transformer (Indoor unit)
4
Stepper motor (x2)
5
Relay
6
Drain pump
7
Float switch
8
Sensor for room temperature
Indoor unit sensor for heat-
9
exchanger
temperature.
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
4. SPECIFICATION OF ELECTRICAL PARTS
TYPE
PAF-230-7-4
EVM45M504UF
ST-9586
MP35EA2
LY2F
PCD-4N230TF-7
FS-085-003E
DTN-C103J40
TYPE
PAF-230-7-4
EEP2H105HQA105
ST-9586
MP35EA2
LY2F
PCD-4N230TF-7
FS-085-003E
DTN-C103J40
www.heronhill.co.uk
SPECIFICATIONS
Output (Rated) 7W, 4 pole, 1 phase, 230V, 50Hz
AC 450V, 0.5µF
AC187~264V
DC12V, 80mNm
AC 240V, 2ab
AC230V, 0.2A
AC230V, 0.5A
°C
Maximum input
38mA
KΩ
Maximum input
34mA
SPECIFICATIONS
Output (Rated) 7W, 4 pole, 1 phase, 230V, 50Hz
AC 500V, 1.0µF
AC187~264V
DC12V, 80mNm
AC 240V, 2ab
AC230V, 0.2A
AC230V, 0.5A
°C
Maximum input
38mA
KΩ
Maximum input
34mA
-9-
15
20
25
30
16.1
12.6
10.0
8.0
°C
–12
0
25
62.29 32.82
10.0
15
20
25
30
16.1
12.6
10.0
8.0
°C
–12
0
25
KΩ
62.29 32.82
10.0
Fax: 01823 665807
40
5.2
50
3.59
40
5.2
50
3.59