CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE
8.10. Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
1. Cooling and Soft Dry Mode
• • • • When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature (Lower temperature: 16°C). This operation automatically will be running under SHi Fan Speed (Cooling), Lo-
Fan Speed (Soft Dry).
• • • • Vertical Airflow Direction:-
In "Manual" setting, the vane will automatically shift down 10° lower than previous setting.
In "Auto" setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°
downward.
2. Heating Mode
• • • • When the Powerful Mode is set, the set temperature will be automatically increased 3°C against the present setting
temperature (Higher temperature: 30°C).
• • • • The Fan Speed will shift as shown below:
• • • • Vertical Airflow Direction:-
In "Manual" setting, the vane will automatically shift down 5° lower than previous setting.
In "Auto" setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
3. Powerful mode will operate for 15 minutes only.
4. Powerful Mode will stop if:
• • • • Powerful mode button is pressed again.
• • • • Stopped by ON / OFF switch.
• • • • Timer-off activates.
• • • • Quiet mode button is pressed.
• • • • Operating mode button is changed.
30