Page 2
A New Dimension in Air Quality and Comfort Experience a new dimension in comfort with Panasonic's new air conditioners. Better air quality than ever, surprising energy savings and fine temperature control – these advanced models have it all.
Model Line-Up Single Inverter Split Deluxe Indoor p.10 CS-E9GKR Capacity (CU-E9GKR) (kW) CS-E12GKR (CU-E12GKR) CS-E15GKR (CU-E15GKR) ATROL ATROL -ion -ion Exclusive SENSOR SENSOR QUIET Air Purifying System Air Purifying System CS-E9GKR/E12GKR Features Single Split Wall-Mounted Deluxe Indoor p.12 CS-W7DKR Capacity (CU-W7DKR) (kW) CS-W9DKR...
Page 4
For an air conditioner with a dust collection system that releases negative ions from an ion generator to negatively charge dust particles and then collect them with the entire surface of a positively charged filter. (As of June, 2007)
Page 5
3 trillion is the simulated number of active e-ions under the mentioned conditions. Actual measured active e-ions at the centre of the room (13m ):100k/cc Calculated number of active e-ions in the entire room assuming they are evenly distributed.
Page 6
When dirt is detected, the air purifying function is started to immediately clean the air in the room. How It Works Monitoring Whether the air conditioner is operating or not, the sensor constantly monitors dirt in the air. Detection The sensor measures the dirt...
Page 7
*1 For an air conditioner with a dust collection system that releases negative ions from an ion generator to negatively charge dust particles and then collect them with the entire surface of a positively charged filter. (As of June, 2007)
Page 8
An inverter is a type of power conversion circuit that electronically regulates the voltage, current, and frequency of a device. In an inverter air conditioner, this circuit controls the revolutions of the compressor — and hence the air conditioner’s output. Raising the frequency increases the output, lowering the frequency reduces it.
Page 9
Indoor and outdoor temperature: 7ºC/ Setting temperature: 25ºC/ Fan speed: High * Comparison of cumulative electricity consumption during 8 hours of cooling (Panasonic in-house comparison) Test conditions: Room temperature at start: 35ºC/ Setting temperature: 25ºC DC Inverter (Hyper Wave Inverter) Original Panasonic inverter circuit technology provides detailed motor current control.
Page 10
Single Inverter Split Wall-Mounted Deluxe Model No CS-E9GKR Capacity(kW) 2.60 (0.80~3.00)/3.60(0.80~5.00) (Btu/h) 8,870(2,730~10,200)/12,300(2,730~17,100) EER/COP(W/W) 4.33/4.26 Star Rating 6.0/6.0 ATROL ATROL -ion -ion SENSOR SENSOR Air Purifying System Air Purifying System CS-E12GKR 3.50(0.80~4.00)/4.90(0.80~6.70) 11,900(2,730~13,600)/16,700(2,730~22,800) 3.63/3.89 6.0/5.5 QUIET QUIET QUIET CS-E9GKR/E12GKR CU-E15GKR Reverse cycle Cooling CU-E9GKR/...
Page 11
Reverse cycle Cooling /Heating Standard Deluxe Wide Model No CS-E18GKR Capacity(kW) 5.30 (0.90~6.00)/6.60(0.90~8.00) (Btu/h) 18,100(3,070~20,500)/22,500(3,070~27,300) EER/COP(W/W) 3.21/3.69 Star Rating 5.0/5.0 CS-E24GKR Model No Capacity(kW) 7.40(0.90~8.10)/8.60(0.90~9.90) 25,200(3,070~27,600)/29,300(3,070~33,800) (Btu/h) EER/COP(W/W) 3.02/3.43 Star Rating 4.0/4.0 ATROL ATROL -ion -ion SENSOR SENSOR Air Purifying System Air Purifying System CU-E18GKR Feature Comparison...
Page 12
Single Split Wall-Mounted Deluxe CS-W7DKR Model No Capacity(kW) 2.30/2.45 7,840/8,350 (Btu/h) EER/COP(W/W) 3.19/3.58 Star Rating 5.0/6.0 Deluxe Wide Model No CS-W18DKR Capacity(kW) 5.30/5.75 (Btu/h) 18,100/19,600 EER/COP(W/W) 2.93/3.19 Star Rating 4.0/3.5 Supersonic Air Purifying System with SUPER alleru-buster Faster dust collection Supersonic Air Purifying System The Supersonic Air Purifying System incorporated in the indoor unit generates supersonic waves.
Page 13
Feature Comparison e-ion Air Purifying System Patrol Sensor Supersonic Air Purifying System SUPER alleru-buster filter Ion Freshener Deodorising Filter One-Touch Air Filter Odour-Removing Function Removable, Washable Panel Inverter Control Indoor Quiet Mode mode Outdoor Powerful Mode Soft Dry Operation Mode Wide &...
Page 14
As quiet as a sound of leaves on a tree Approx. 20dB 40dB * Based on in-house Panasonic measurement standards Powerful Mode Pressing the Powerful button cools or heats the room quickly. It provides fast comfort, with full power and a strong airflow.
Page 15
Panasonic HA Air-Conditioning (M) Sdn. Bnd. (PHAAM) Registration No.: AR 1010 This Panasonic air conditioner factory in Malaysia has received ISO 9001 certification. ISO 9001 Certification attests to the excellent quality assurance systems in place at this factory. About ISO 9001 Certification...
Ph: (02) 9986 7400 Fax: (02) 9986 7600 Visit our website at: www.panasonic.com.au or email our Customer Care Centre on pacc@panasonic.com.au Specifications are subject to change without notice. While every effort has been made to represent product colours accurately, slight variation may occur due to the printing process. TV pictures are simulated in an effort to explain product features.