Note:
1. 24 times checking: Actual Ion ON for 10s & OFF for 30 min continuously for 24 times.
2. 24 times count will be cleared when either one of the following conditions happen.
a) 24 times count over, b) Ionizer cancel if press Ion button or power reset, c) Ion feedback signal is OK.
3. Error protection will be cleared when one of the following conditions happen.
a) Power reset, b) Remote control operation ON/OFF button press, c) Auto operation switch press, d) Operation OFF due
to Timer OFF
4. Ion auto restart: Ion will auto restart if actual Ion was ON with no error protection control during power shutdown. Otherwise
Ion will not auto restart.
5. Ion LED blinking can ON/OFF during error protection by following conditions:
a) Press remote control ion button
b) Press Auto operation switch to OFF blinking.