Evaporator
1.5 ∅ x700L (1.5 ∅x1400L;G-AR)
1.5 ∅ x900L (1.5 ∅x1400L;G-AR)
1.5 ∅ x700L (1.5 ∅x1300L;G-AR)
* When servicing the cycle, be sure to change the strainer for the dryer.
Conditions
RAC-24G-AR
RAC-24G2B, 24GE2B, 24G2L High temperature
Note : Measure the heat exchanger temperature at the center of U-bend.
(By means of thermistor thermometer)
5. REFRIGERATING CYCLE DIAGRAM
Compressor
Suction Pipe
Surface temp. of heat exchanger
interchanging pipe (°C)
Standard
High temperature
Low temperature
Standard
13
Low temperature
Discharge Pipe
Strainer (Dryer)
T
T
1
2
8
54
14
73
-1
40
8
51
74
0
41
– 8 –
FILE NO. SVM-06051
Condenser
Capillary Tube(Comp injection)
(1 pcs)
(1.0 ∅ x700L)
Ambient temp. conditions
DB/WB (°C)
Indoor
Outdoor
27/19.5
35/24
32/22.5
52/24
21/15.5
21/15.5
29/19
46/24
32/22.5
52/24
21/16
21/16