Systematic Refrigerating Cycle Diagram - Toshiba RAV-HM401CTP Series Service Manual

Table of Contents

Advertisement

3. SYSTEMATIC REFRIGERATING CYCLE DIAGRAM

Indoor Unit
• Single type (Combination of 1 indoor unit and 1 outdoor unit)
(Indoor unit)
Distributor
(Strainer incorporated)
TCJ sensor
exchanger
TC sensor
Liquid side
(Outer dia : ØB)
To outdoor unit
Dimension table
Outer diameter of refrigerant pipe
Indoor unit
Gas side ØA
HM40, HM56 type
HM80, 90,110
140, 160 type
• Twin type (Combination of 2 indoor units and 1 outdoor unit)
(Indoor unit A)
Distributor
(Strainer incorporated)
TCJ sensor
exchanger
TC sensor
Liquid side
(Outer dia : ØA)
Branch pipe
Liquid side
(Outer dia : ØC)
To outdoor unit
Indoor unit
Branch pipe
HM56 × 2
RBC-TWP30E2
Strainer
Heat
Gas side
(Outer dia : ØA)
To outdoor unit
Liquid side ØB
12.7
6.4
15.9
9.5
Strainer
Heat
Gas side
(Outer dia : ØB)
A
B
6.4
12.7
Heating
Cooling
Capillary tube specifications
Model
RAV-HM∗∗∗CTP∗
HM40, HM56 type
HM80 type
HM901, 110,
140, 160 type
(Indoor unit B)
Distributor
(Strainer incorporated)
TC sensor
Liquid side
(Outer dia : ØA)
Branch pipe
Liquid side
(Outer dia : ØD)
C
D
9.5
15.9
- 21 -
Inner dia. × Length × Q'ty
Ø2 × 300 × 1, Ø2 × 350 × 1
Ø2 × 800 × 1
Ø2 ×
300
× 1, Ø2 × 350 × 2
Ø2 × 400 × 1
Ø2 × 150 × 1, Ø2 × 200 × 2
Ø2 × 250 × 1, Ø2 × 300 × 1
Ø2 × 350 × 1, Ø2 × 1000 × 1
Heating
Cooling
TCJ sensor
Strainer
Heat
exchanger
Gas side
(Outer dia : ØB)
To outdoor unit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents