Safety Precautions
Operating Instructions
Installation Instructions
Care and Cleaning
Troubleshooting Tips
Remote Control and App
Instructions
Warning notices: Before using this product,
please read this manual carefully and keep
it for future reference.
change without prior notice for product
improvement. Consult with your dealer or
the manufacturer for details.
www.toshiba-lifestyle.com

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAC-WK0512CMRU

  • Page 1 Troubleshooting Tips Remote Control and App Instructions USER MANUAL Window Type Room Air Conditioner RAC-WK0512CMRU (5,000 BTU) Warning notices: Before using this product, please read this manual carefully and keep RAC-WK0612CRRU (6,000 BTU) it for future reference. RAC-WK0812ESCWRU (8,000 BTU)
  • Page 2: Read This Manual

    Read This Manual Inside you’ll nd many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
  • Page 3 To prevent injury to the user or other people and property damage, the instructions shown here must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The level of risk is shown by the following indications. This symbol indicates a hazardous situation which, if not avoided, WARNING could result in death or serious injury.
  • Page 4 WARNING • Do not damage or use an alternate power cord. re and electric shock. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service ed person in order to avoid a hazard. ow straight into persons to avoid possible health hazard.
  • Page 5 CAUTION This could injure the pet or harm the plant. • Hold the plug by the head of the power plug when taking it out. Otherwise, it may cause electric shock and damage. • Ensure that the installation is properly secured to prevent the product from potentially falling. •...
  • Page 6 • Keep ventilation openings clear of obstruction. • Unit is only to be serviced by a Toshiba authorized servicer, please call Customer Service at 1-855-204-5313 for support. • Flammable refrigerant R32 is used within air conditioner. Please follow the instructions carefully to handle, install, clean, and service the air conditioner to avoid damage or hazard.
  • Page 7 The power supply cord contains a current measuring device that detects damage to the Plug in & press RESET power cord. Test your power supply cord as follows: RESET 1. Plug in the air conditioner. 2. The power supply cord will have TWO TEST buttons on the plug head.
  • Page 8 RAC-WK05 Model High Pitched Sound High efficiency compressors may have a high pitched sound during Trickling Sound Sound of Rushing Air cooling cycle. Droplets of water In front of the unit, you hitting condenser may hear the sound of during normal rushing air being moved operation may cause by the fan.
  • Page 9 RAC-WK08 / RAC-WK10 / RAC-WK12 / RAC-WK15 Models High Pitched Sound High efficiency compressors may Sound of Rushing Air Trickling Sound have a high pitched sound during In front of the unit, you cooling cycle. Droplets of water may hear the sound of hitting condenser rushing air being moved during normal...
  • Page 10: Air Direction

    Air Conditioner Features (general) WARNING To reduce the risk o read the SAFETY PRECAUTIONS before operating this appliance. This air conditioner is designed to be operated under the following conditions: Outdoor temp.: 64 ~ 109°F / 18 ~ 43°C Cooling Operation Indoor temp.: 62 ~ 90°F / 17 ~ 32°C NOTICE...
  • Page 11: Fan Mode

    FRESH AIR VENT CONTROL (RAC-WK10/12/15 Models) Fig. A (VENT CLOSED) Fig. B (VENT OPEN) Fig. C (VENT & EXHAUST OPEN) The Fresh Air Vent allows the air conditioner to: Recirculate inside air – Vent Closed (See Fig. A) Draw fresh air into the room - Vent Open (See Fig. B) Exchange air from the room and draw fresh air into the room - Vent and Exhaust Open (See Fig.
  • Page 12 Air Conditioner Features (Models RAC-WK06 / 08 / 10 / 12 / 15) Electronic Control Operating Instructions Before you begin, thoroughly familiarize yourself with the control panel as shown below and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control alone, with the remote, or with the app (some models).
  • Page 13 Key Pad Features (Models RAC-WK08 / 10 / 12 / 15) Connect Indicator Light Power Display (Smart models only) Button Energy Clean Timer Sleep Up ( ) and Down ( ) Mode Saver Filter Button Button Button Buttons Button TO TURN UNIT ON OR OFF: The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again.
  • Page 14 When operating on Auto mode: The selected time will register in 5 seconds, and the system will automatically revert back When you set the air conditioner to AUTO to display the previous temperature setting or mode, it will automatically select cooling room temperature when the unit is on.
  • Page 15: Installation Instructions

    INSTALLATION INSTRUCTIONS Window Requirements Before You Begin WARNING Your air conditioner is designed to install in standard Read these instructions completely and double hung windows with opening widths of 23” to carefully. 36” (584mm to 914mm). • IMPORTANT - Save these instructions. Fig.
  • Page 16: Prepare The Air Conditioner

    1. Prepare the Window Lower sash must to allow a clear vertical opening (see dimension H in Table 1). Side louvers and the rear of the AC must have clear air space to allow enough air ow through the condenser for heat removal. The rear of the unit must be outdoors, not inside a building or garage. Mounting Hardware NOTICE Weather stripping is only for...
  • Page 17 RAC-WK05/06 Models RAC-WK08 Model C. Align the hole in the top rail with those in the top of the unit as shown in Fig. E. Fig.B D. Secure the top rail to the unit with the 3/8” Screws as Fig.C shown in Fig.
  • Page 18 B. Slide the free end “ “ section of the panel directly into the Fig. 2 “ “ section “I” section cabinet as shown in Fig. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
  • Page 19 B. Extend the side panels out against the window frame (Fig. 6). Fig. 6 window frame 5. Secure Air Conditioner A. Place the frame lock between the frame extensions and the window sill as shown (Fig. 7A for Wooden windows), (Fig. 7B for Vinyl-Clad windows). Drive 3/4”...
  • Page 20 6. Install Weather Stripping (ENERGY STAR models only) In order to minimize air leaks between the room air conditoner and the window opening, trim the weather stripping to the proper rotective backing and plug any gaps if needed (Fig. 11). Fig.
  • Page 21: Care And Cleaning

    CARE AND CLEANING CAUTION Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prev re hazards. Air Filter Cleaning RAC-WK05 only lter should be checked at least once a month to lter can build up and cause an accumulation of frost on the cooling coils.
  • Page 22 Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Problem Solution rmly into wall outlet. Circuit breaker tripped. Reset circuit breaker. Air conditioner , press the RESET button.
  • Page 23 Problem Solution Air conditioner lter. Outside temperature extremely hot. Set FAN speed to a higher setting to bring rapidly. air past cooling coils more frequently. Check for potential obstructions blocking the outdoor intake/exhaust. Clear any obstructions. Air movement sound. This is normal. If too loud, set to a slower FAN setting. Noise when unit is Window vibration - poor installation.
  • Page 24: Handling The Remote Control

    REMOTE CONTROL AND APP INSTRUCTIONS Handling the Remote Control Location of the remote control Use the remote control within a distance of 26.2 ft (8 meters) from the air conditioner, pointing it towards the receiver. Reception is c med by a beep. CAUTION •...
  • Page 25: Function Buttons

    REMOTE CONTROL AND APP INSTRUCTIONS cations RG57J4(B)/BGCEU1 Rated voltage 3.0V (Dry batteries R03/LR03x2) Signal receiving range 26 ft. (approx. 8 m) Environment 23°F ~ 140°F (-5°C ~ 60°C) Function Buttons Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control.
  • Page 26: Inserting And Replacing Batteries

    Handling the Remote Control NOT SURE WHAT A FUNCTION DOES? Refer to the Operating Instructions section of this manual for a detailed description of the functions available using the remote. NOTICE Button designs on your unit may di er slightly from the example shown. If the unit does not have a specic function, using that function’s button on the remote control will have no e ect.
  • Page 27 Remote LED Screen Indicators Transmission Indicator Lights up when remote sends signal to unit MODE display ON/OFF display Displays the current Appears when the remote is enabled and can send a signal to the unit. mode, including: If you would like to turn the remote off without affecting the unit, point the remote away from the unit and press the ON/OFF button.
  • Page 28: Basic Functions

    Basic Functions SETTING THE DESIRED TEMPERATURE The operating temperature range for this unit is 62°F-86°F (17-30°C). You can increase or decrease the set temperature in 1°F or 1°C increments. Changing the Mode 1. To change the operating mode, press the MODE button until the desired mode appears on the remote’s display.
  • Page 29: Timer Functions

    Timer Functions Your air conditioning unit has two timer-related functions: TIMER ON - sets the amount of time after which the unit will automatically turn on. TIMER ON TIMER ON TIMER OFF - sets the amount of time after which the unit will automatically turn o .
  • Page 30 Timer Functions (cont.) 3. Wait 2 seconds, then the TIMER OFF function will be activated. The digital display on your remote control will then return to the temperature display. Timer on NOTICE Continue When setting the TIMER ON or TIMER OFF functions, up to 10 to press hours, the time will increase in 30 minute increments with each TIMER ON...
  • Page 31: How To Use The Advanced Functions

    How to Use the Advanced Functions SLEEP Function The SLEEP function is used to decrease energy use while you sleep (and don’t need the same temperature settings to stay comfortable). Note: The SLEEP function is not available in FAN or DRY mode. ECO button Press this button to activate the SHORTCUT Function...
  • Page 32: Declaration Of Conformity

    OS may or may not be supported until a new version is c mobile phone or problems in your network may prevent the system from working and Toshiba will not be responsible for any problems that could be caused by incompatibility or network issues.
  • Page 33: System Overview

    DOWNLOAD AND INSTALL THE APP Scan to download app. • You can also go to Google Play or App Store and search for Toshiba NA AC. For more information, please refer to Toshiba Lifestyle website: www.toshiba-lifestyle.com NOTICE All the images in this manual are for reference only, your product and app may look slightly di erent.
  • Page 34 • Make sure your smartphone is connected to your wireless router and your wireless router has a working 2.4GHz internet connection. • It is recommended to activate your account immediately to be able to recover your password by email. 6.1 Press “Sign Up”. 6.2 Enter your email address and password.
  • Page 35 ADDITIONAL APP AND SMART HOME FUNCTIONS For additional instructions regarding the features of the app and Smart Home skill capabilities, scan the QR code below. Declaration of conformity CONTAINS FCC ID: 2ADQOMDNA21 CONTAINS IC : 12575A-MDNA21 This device complies with Part 15 of the FCC Rules and it contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
  • Page 36: Supplier's Declaration Of Conformity

    If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information Unique Identifier: TOSHIBA brand, RG57J4(B)/BGCEU1 Responsible Party U.S. Contact Information Midea America Corporation 300 Kimball Dr...
  • Page 37: Instrucciones De Operación

    Instrucciones del Control Remoto y del App MANUAL DEL USUARIO Tipo de Ventana/Pared Aire Acondicionado de Cuarto RAC-WK0512CMRU (5,000 BTU) Avisos de advertencia: antes de usar este producto, lea atentamente este manual y RAC-WK0612CRRU (6,000 BTU) consérvelo para futuras referencias.
  • Page 38: Manual Del Propietario

    Manual del propietario Precauciones de Seguridad ....................38 Instrucciones de Operación ....................40 Instrucciones de Instalación ....................47 Mantenimiento y Limpieza ....................53 Soluciones de Problemas ....................54 Instrucciones del Control Remoto y del App .............. 60 Lea este Manual En su interior encontrará...
  • Page 39 Para evitar daños al usuario u otras personas y a la propiedad, las instrucciones que se muestran aquí deben ser seguidas. Las operaciones incorrectas por la ignora de las instrucciones podría causar perjuicios cado por las siguientes indicaciones. Este símbolo indica una situación peligrosa que, si no evitada, podría ADVERTENCIA causar la muerte o lesiones graves.
  • Page 40 ADVERTENCIA que la unidad. Puede causar fallas y descarga eléctrica. • No dañe ni utilice un cable de alimentación alternativo. Puede causar incendio y descarga eléctrica. Si el cable de alimentación está dañado, debe ser reemplazado por el fabricante o un centro de cada para evitar un peligro.
  • Page 41 PRECAUCIÓN • Limpie solo con un paño suave. No utilice detergentes fuertes que contengan cera o diluyentes, ya que puede dañar el producto. lados podrían causar lesiones. • No limpie el acondicionador de aire con agua. • El agua puede entrar en la unidad y degradar el aislamiento que podría conducir a una descarga eléctrica.
  • Page 42 Mantenga las aberturas de ventilación libres de obstrucciones. • La unidad solo debe ser atendida por un centro de asistencia autorizada Toshiba, llame al Servicio al Cliente al 1-855-204-5313 para obtener asistencia técnica. amable R32 se usa dentro del acondicionador de aire. Siga las instrucciones cuidadosamente para manejar, instalar, limpiar y reparar el acondicionador de aire para evitar daños o peligros.
  • Page 43 El cable de energía contiene un dispositivo de medición que detecta daños en el proprio cable. Enchufe y pulse Pruebelo de la siguiente manera: el botón RESET 1. Enchufe el acondicionador de aire. RESET 2. El cable de energía tendrá DOS botones en el cabezal del enchufe.
  • Page 44 Modelo RAC-WK05 Sonido Agudo Compresores de alto rendimiento pueden presentar un sonido agudo Sonido de Corriente Sonido de Goteo durante el ciclo de enfriamiento. del Aire Las gotas de agua que caen sobre el Delante de la unidad, es posible que escuche el condensador durante sonido de corriente de aire la normal operación...
  • Page 45 Modelos RAC-WK08 / RAC-WK10 / RAC-WK12 / RAC-WK15 Sonido Agudo Compresores de alto rendimiento pueden presentar un sonido agudo Sonido de Corriente Sonido de Goteo durante el ciclo de enfriamiento. del Aire Las gotas de agua que caen sobre el Delante de la unidad, es condensador durante posible que escuche el...
  • Page 46 Características del condicionador de aire (general) ADVERTENCIA Para reducir el riesgo de incendio, descargas eléctricas o lesiones a personas o propiedades, lea las PRECAUCIONES DE SEGURIDAD antes de utilizar este aparato. Este acondicionador de aire está diseñado para funcionar en las siguientes condiciones: Temperatura exterior: 64 ~ 109°F / 18 ~ 43°C Operación de...
  • Page 47 12/15) Fig. A (VENTILACIÓN CERRADA) Fig. B (VENTILACIÓN ABIERTA) Fig. C (VENT Y SALIDA ABIERTAS) La ventilación de aire fresco permite al acondicionador de aire: Recircular el aire interior – Ventilación Cerrada (Ver Fig. A) Sacar aire fresco a la habitación – Ventilación Abierta (Ver Fig. B) Cambiar el aire de la habitación y exprimir el aire fresco en la habitación - Ventilación y Salida Abiertas (ver Fig.
  • Page 48 Características del acondicionador de aire (Modelos RAC-WK06/08/10/12/15) Instrucciones de operación del control electrónico Antes de comenzar, familiarícese completamente con el panel de control como se muestra a continuación y todas sus funciones, luego siga el símbolo de las funciones que desee. La unidad se puede controlar solo con el control de la unidad, con el control remoto o con la aplicación (algunos modelos).
  • Page 49 Características del teclado (Modelos RAC-WK08/10/12/15) Visor Luz Indicadora de conexión Botón Power (Solo modelos Smart) Encender/Apagar Ahorro de Filtro de Botón Botón Botones Botón Botón Energía Limpieza Temporizador Sueño Modo Arriba ( ) y Abajo ( ) Ventilador PARA ENCENDER O APAGAR LA UNIDAD: El programa de modo de suspensión se puede Pulse el botón de encendido para encender o apagar cancelar en cualquier momento durante el...
  • Page 50 Cuando se opera en modo Automático: El tiempo seleccionado se registrará en 5 segundos, y el sistema revertirá automáticamente Al ajustar el acondicionador de aire al modo AUTO, guración de la temperatura seleccionará automáticamente el enfriamiento o el anterior o la temperatura ambiente cuando la funcionamiento solo del ventilador dependiendo unidad está...
  • Page 51: Instrucciones De Instalación

    INSTRUCCIONES DE INSTALACIÓN Requisitos de la ventana Antes de empezar ADVERTENCIA Su acondicionador de aire está diseñado para Lea estas instrucciones completa y instalarse en ventanas estándar dobles colgadas con cuidadosamente. anchos de apertura de 23” a 36” (584 mm a 914 mm). •...
  • Page 52 1. Prepare la ventana ciente para permitir una apertura vertical clara (véase la dimensión H del Cuadro 1). Las rejillas laterales y la parte trasera del acondicionador ciente a través del condensador para la cio o garaje. Accesorios de montaje AVISO Banda Adesiva es solo para los modelos ENERGY STAR.
  • Page 53 Modelos RAC-WK05/06 Modelo RAC-WK08 C. Alinee el agujero en el carril superior con los de la parte superior de la unidad como Fig.B se muestra en la Fig. E. D. Fije el carril superior a la unidad con los tornillos de Fig.C 3/8”...
  • Page 54 B. Deslice la sección “ ” del panel directamente en el gabinete Fig. 2 “ “ Sección “I” section como se muestra en la Fig. 2. Deslice el panel hacia abajo. Asegúrese de dejar te espacio para deslizar la parte superior e inferior del marco en los carriles del gabinete.
  • Page 55 B. Extienda los paneles laterales contra el marco de la ventana Fig. 6 (Fig. 6). Marco de window la ventana frame 5. Acondicionador de Aire seguro A. Coloque el bloqueo de los marcos entre las extensiones del marco y el umbral de la ventana como se muestra (Fig.
  • Page 56 6. Instalación de la Banda Adesiva (solo modelos ENERGY STAR) n de minimizar las fugas de aire entre el acondicionador de aire de la habitación y la abertura de la ventana, recorte la banda adesiva a la longitud adecuada, despegue el respaldo protector y enchufe cualquier hueco si es necesario (Fig.
  • Page 57: Mantenimiento Y Limpieza

    MANTENIMIENTO Y LIMPIEZA PRECAUCIÓN Limpie su acondicionador de aire de vez en cuando para mantenerlo con un aspecto nuevo. Asegúrese de desenchufar la unidad antes de limpiarla para evitar descargas eléctricas o incendios. ltro de aire RAC-WK05 solamente ltro de aire deberá revisarse cuando menos una car si es necesario limpiarlo.
  • Page 58 Antes de llamar al servicio técnico, revise esta lista. Puede ahorrarle una gran cantidad de tiempo y dinero. Esta lista incluye ocurrencias comunes que no son consecuencia de un trabajo o materiales defectuosos en el equipo. Problema Solución rmemente el enchufe en la toma de pared.
  • Page 59 Problema Solución ltro. Consulte la sección Cuidado y Limpieza. Para descongelar, establezca el modo FAN ONLY. Acondicionador de aire enfriándose, guración más baja. pero el ambiente Rejillas direccionales de aire colocadas incorrectamente. Pivotee las rejillas hasta obtener está demasiado una mejor distribución del aire. templado - NO hay formación de La parte delantera de la unidad está...
  • Page 60: Manejo Del Control Remoto

    INSTRUCCIONES DEL CONTROL REMOTO Y DEL APP Manejo del Control Remoto Ubicación del control remoto Utilice el control remoto a distancia a una distancia de 8 metros del acondicionador de aire, apuntando hacia el receptor. La recepción se rma con un pitido. PRECAUCIÓN •...
  • Page 61: Funcionamiento De Los Botones

    INSTRUCCIONES DEL CONTROL REMOTO Y DEL APP caciones del Control Remoto Model RG57J4(B)/BGCEU1 Voltaje nominal 3.0V (Dry batteries R03/LR03x2) Faja de recepción de señal 26 ft. (aprox. 8 m) Ambiente 23°F ~ 140°F (-5°C ~ 60°C) Funcionamiento de los Botones Antes de empezar a utilizar el nuevo acondicionador de aire, asegúrese de familiarizarse con su control remoto.
  • Page 62: Eliminación De Baterías

    ¿NO ESTÁ SEGURO DE ALGUNA FUNCIONALIDAD? Consulte la sección Instrucciones de Funcionamiento de este manual para obtener una descripción detallada de las funciones disponibles en el uso del control remoto. Los diseños de los botones de su unidad pueden diferir ligeramente del ejemplo enseñado. tón de esa función en el control remoto no tendrá...
  • Page 63 Indicadores de la pantalla de LEDs del Control Remoto Indicador de Transmisión Enciende cuando el control remoto envía una señal a la unidad Indicador de ON/OFF Aparece cuando el control remoto está habilitado y puede enviar una señal a la unidad. Si desea apagar el control remoto sin afectar la unidad, apunte el control remoto lejos de la unidad y presione el botón ON / OFF.
  • Page 64: Funciones Básicas

    Funciones Básicas AJUSTANDO LA TEMPERATURA DESEADA El alcanze de la c de 62°F a 86°F (17°C - 30°C). Se puede aumentar o disminuir la temperatura ajustada en incrementos de 1°F o 1°C. Cambiando el Modo 1. Para cambiar el modo de funcionamiento, pulse el botón MODE hasta que aparezca el modo deseado en la pantalla del control remoto.
  • Page 65 Su acondicionador de aire tiene dos funciones relacionadas con el temporizador: TIMER ON - c del la hora después de la cual la unidad se encenderá automáticamente. TIMER ON TIMER ON TIMER OFF - c del la hora después de la cual la unidad se apagará...
  • Page 66 Funciones del Timer (cont.) 3. Espere 2 segundos y se activará la función TIMER OFF. El indicador digital del control remoto volverá al indicador de temperatura. Timer on AVISO Continúe presionando gurar las funciones TIMER ON o TIMER OFF, hasta 10 horas, TIMER ON o el tiempo aumentará...
  • Page 67 Cómo utilizar las funciones avanzadas Función SLEEP La función SLEEP es usada para ahorar energía mientras del sueño (y no necesita los ajustes de temperatura para mantenerse cómodo). Nota: La función SLEEP no está disponible en modo FAN o DRY Botón ECO Pulse este botón para activar el modo de ahorro de energía.
  • Page 68: Declaración De Conformidad

    Toshiba no será responsable de ningún problema que pueda ser causado por incompatibilidad o problemas de red.
  • Page 69: Visión General Del Sistema

    Código QR de Apple Escanear para descargar la aplicación. • También puede ir a Google Play o App Store y buscar Toshiba NA AC. Para obtener más información, consulte la página web de Toshiba Lifestyle: www.toshiba-lifestyle.com AVISO Todas las imágenes de este manual son solo para referencia, su producto y aplicación pueden tener un aspecto ligeramente diferente.
  • Page 70 • Asegúrese de que su Smartphone esté conectado a su router inalámbrico y que su router inalámbrico tenga una conexión a Internet de 2,4 GHz. • Se recomienda activar su cuenta inmediatamente para poder recuperar su contraseña por correo electrónico. 6.1 Pulse “Registrarse”.
  • Page 71 FUNCIONES ADICIONALES DE LA APLICACIÓN Y SMART HOME Para obtener instrucciones adicionales sobre las características de la aplicación y las capacidades del sistema Smart Home, escanee el código QR a continuación Declaración de conformidad CONTIENE FCC ID: 2ADQOMDNA21 CONTIENE IC: 12575A-MDNA21 Este dispositivo cumple con la Parte 15 de las Reglas FCC y contiene transmisores/ receptores libres de licencia que cumplen con los RSS de Innovación, Ciencia y Desarrollo Económico de Canadá...
  • Page 72 Si sospecha que alguien ingirió la batería o que la colocó dentro de alguna parte del cuerpo, busque atención médica de inmediato. Declaración de conformidad del proveedor 47 CFR § 2.1077 Información sobre el cumplimiento Identificador único:TOSHIBA brand, RG57J4(B)/BGCEU1 Parte responsable Información de contacto de los Estados Unidos Midea America Corporation 300 Kimball Dr...