ITEM
Capacity*
Power source
Power consumption
Power factor
Running current
Starting current
Moisture removal
Indoor (Hi/Low)
Noise
Outdoor (Hi/Low)
Compressor output
Fan motor output
Name of refrigerant
Refrigerant
Charge volume
High Fan
Air volume
Medium Fan
Low Fan
Refrigerant control
Safety device
Control device
Ventilation
Auto louver
Height
Dimensions
Width
Depth
Net weight
Usable outdoor temperature range
Specification are subject to change without notice.
Note : Capacity is based on the following temperature conditions. (*)
ITEM
Indoor unit inlet air temperature
Outdoor unit inlet air temperature

1. SPECIFICATIONS

MODEL
RAC-24GE2B
COOLING (SSA)
k cal/h
4,800
Btu/h
5,600 (W)
4,000 (W)
Phase
Single
V
220
Hz
60
W
3,750
%
97
A
17.5
A
65
lit/h
3.7
dB
58/53
dB
64/59
W
2,000
W
200
R22
kg
0.90
3
m
/h
1,050
3
m
/h
m
3
/h
850
Over current relay for protection of compressor motor and fan motor
Selector switch, Thermostat, Auto louver switch
mm
mm
mm
kg
72
°C
MODE
(DB)
(WB)
(DB)
(WB)
– 3 –
RAC-24G2B
HEATING
COOLING (SSA) COOLING (JIS) COOLING (JIS)
3,440
4,800
5,600 (W)
Single
220
60
4,400
3,750
100
97
20.0
17.5
65
3.7
58/53
64/59
2,000
200
R22
0.90
1,050
850
Capillary tube
Yes
Yes
435
660
748
70
MAX. 52
SSA 385/386
COOLING
29°C
19°C
46°C
24°C
FILE NO. SVM-06051
RAC-24G-AR
RAC-24G2L
6,500 (W)
6,500 (W)
Single
Single
220 – 240
220
50
60
3,100
3,200
93
96
14.5
15.1
58
65
3.7
3.7
58/53,60/55
58/53
64/59,66/62
64/59
2,200
2,000
200
200
R22
R22
1.05
0.90
1,050
1,050
850
850
70
70
JIS
COOLING
27°C
19.5°C
35°C
24°C