Carriage Motor / Timing Belt Removal - Epson 1240U Service Manual

Color image scanner
Hide thumbs Also See for 1240U:
Table of Contents

Advertisement

EPSON Perfection 1240U

4.2.6 Carriage Motor / Timing Belt Removal

1. Release the Carriage Lock. (See Section 4.2.1.)
2. Remove the Document Cover. (See Section 4.2.2.)
3. Remove the Upper Housing. (See Section 4.2.3.)
4. Remove the Carriage Unit. (See Steps 1-8 in Section 4.2.5.)
5. Remove the six screws (gold, CBP, M3x8) and then remove the
main board cover.
6. Remove the screw (gold, CBP, M3x8) securing the CR Motor Unit.
7. Disconnect the cable for the CR Motor Unit from the connector on
the main board, and then remove the CR Motor Unit.
Assembly and Disassembly
5. Main Board Cover
Disassembly Procedures
5. CBS Screw (M3x8)
5. CBS Screws (M3x8)
Figure 4-20. Shield Plate Removal
7. Connector
Figure 4-21. CR Motor Unit Removal
Revision A
6. CBS Screws (M3x8)
FFC Cable
CR Motor Unit
36