EPSON Perfection 1240U
6. Disconnect the connector for the Inverter Lamp from the Inverter
Board.
7. Disconnect the 2-pin connector for the CCD sensor.
8. Release the two hooks, and then remove the Inverter Board.
Assembly and Disassembly
Inverter Board
Connector (2-pin)
Figure 4-10. Inverter Board Removal
Disassembly Procedures
Revision A
Connector
Hooks