EPSON Perfection 1240U

6.1 Overview

This chapter provides information necessary to keep the scanner function in
optimum condition constantly and to prevent troubles.

6.1.1 Cleaning

Perform cleaning when stain is noticeable. Stain on the document glass,
particularly, has a direct effect on scanned images. Therefore, be sure to clean
the glass well to remove stain thoroughly.
Never apply any organic solvents such as thinner or
C A U T I O N
benzene, since these may deteriorate plastic and rubber
parts.
Outer Cases
Wipe dirt off with a clean cloth, moistened with water and squeezed tightly.
To remove severe stains, use a neutral detergent.
Document Glass
Remove dust and paper debris with a dry, clean cloth. If the dirt is severe
or foreign matter is stuck on the glass, use a cloth soaked with neutral
detergent. If any trace is left, wipe it off with a dry, clean cloth again.

6.1.2 Lubrication

You need to lubricate the carriage unit if you have replaced it or notice it
making abnormal noise. See the following tables for the recommended grease
type and points to apply it.
Table 6-1. Recommended Grease
Grease Type
Contents
G-26
40g
*: EPSON exclusive (Not on the market)
Maintenance
Part Number
Availability
B702600001
E *
Overview
Table 6-2. Lubrication Points
Figure
Lubrication Points
Figure 6-1
Transmission gear shaft of the CR motor and
drive pulley shaft.
Figure 6-1
Driven pulley shaft
Excessive lubrication may cause the carriage
C A U T I O N
mechanism to be damaged or operate abnormally.
G-26
G-26
Figure 6-1. Lubrication Points
Revision A
Lubrication
G-26 (1x3 mm) for
each
G-26 (1x3 mm)