Short Parts List - gledhill Stainless Lite HP SOL Indirect 180-400 litres Design, Installation & Servicing Instructions

Stainlesslite hp series unvented cylinders specifically designed to work with a heat pump
Table of Contents

Advertisement

SERVICING AND MAINTENANCE
START
Is pressure downstream
of pressure reducing valve
NO
correct?
YES
Is valve seal and seat
clean & undamaged?
YES
Is heater operating at
less than 60ºC?
NO
Re-set temperature
1
3kW immersion element
2
22mm 90° compression elbow c/w/drain
3
Lift up pressure and temperature relief valve 6 bar 92-95°C
4
Inlet group set at 3 bar c/w expansion relief valve set at 4.75 bar
5
¾" fl exible hose
6
18 litre expansion vessel
7
24 litre expansion vessel
8
Wall mounting bracket for 18/24 litre expansion vessel
9
35 litre expansion vessel
10
Wall mounting bracket for 35 litre expansion vessel
11
22mm 2 port valve (indirects only)
12
Junction wiring box (12 way)
13
Control and overheat limit thermostat
14
15mm x 22mm tundish
15
28mm 2 port valve
NO
Clean or replace
as required
YES
Is expansion vessel
charge pressure correct?
YES
Replace ERV/TPRV
Replace PRV
SPARE PARTS LIST
Description
FAULT - Water Discharge Into Tundish
NO
Recommission
expansion
vessel pressure
YES
Is ERV/TPRV
discharging?
NO
END
FAULT FINDING/SHORT PARTS LIST
Page 27
Quantity
Stock Code No.
1
SH001
1
SF003
1
SG017
1
SG010
1
SG003
1
XG191
1
XG192
1
XG184
1
XG193
1
XG058
1
XG083
1
XG129
1
XG168
1
XG173
1
XC012