Heat/Cool Min Delta
The minimum difference between the heat mode set temperature
and the cool mode set temperature when the system mode is in
Auto Change Over.
Compressor Min Time
Minimum amount of time the compressor will remain off between
calls for heat/cool.
Compressor Min Temp
The minimum outside temperature after which the system will not
activate the compressor (the Smart Thermostat must be connected to
the internet for this feature to function).
Heat Differential Temp
The minimum difference between the current temperature and
set temperature.
Heat Dissipation Time
The amount of time the fan will run after the heat has been turned off.
Max Heat Outdoor Temp
In a heat pump, with auxiliary heat configuration, the thermostat
will not activate the auxiliary heat if the outdoor temperature
exceeds this level.
Cool Differential Temp
The minimum difference between the current temperature and
the set temperature.
Cool Dissipation Time
The amount of time the fan will run after the heat has been turned off.
Temp Correction
This will allow you to offset the temperature displayed on the
Smart Thermostat.
For systems with more than one stage of heating or cooling, the
Smart Thermostat will automatically determine when to turn on the
next stages. It will use a combination of the difference in current
temperature and set temperature and/or minimum run times of the
various stages.
Installer Code
This option lets you enable or disable 3262 as the installer code.
19
Test Equipment
This section will allow you to manually turn on and off the various
equipment connected to the Equipment Interface in order to test
the wiring and connections.
Warning: Compressor protection and minimum run time features
are not enforced while in this mode.
In any of the screens within this section, the equipment will turn off
when you select Done.
Detectors
This section will allow you to configure the detector inputs on the
Equipment Interface. This can be used to connect optional flood
sensors, or other leak detection devices.
Once an input has been triggered it will generate an alert on the
touch screen display as well as send an e-mail if the thermostat has
been registered with a web portal. Each input can be configured
as normally open, where a short circuit between the IN1+ and IN1
will activate the alert, or normally closed where an open circuit will
activate the alert.
To activate any input, select the input and program a name. To
deactivate the input simply delete the name.
View Wiring Diagram
This feature will allow you to view the terminal connections of the
equipment interface as determined by the configuration options
selected during this installation process.

Contractor Info

This section will allow you to enter your contact information. This
will be displayed to the homeowner in the Settings- About menu,
when any alert is shown on the touch screen and in their personal
web portal. You can enter your;
Company name
Phone number
E-mail address
Website address
If you are a register ecobee contractor, you will have access to the
Contractor portal. On this portal you can enter the serial number of
the ecobee Smart Thermostat you install. Once those thermostats
20