Performing Feed Correction to Alleviate Horizontal Bands and the Like

Procedure
1.
Print a test pattern.
MENU
CALIBRATION
CALIBRATION
TEST PRINT
2.
Read the correction values from the test pattern.
In the printing example shown below, "-0.40" becomes the correction value.
Test pattern
Gap present
3.
Enter the correction values that you read.
SETTING
0.00%
- 0.40%
4.
Go back to the original screen.
W 1346mm
SETUP SHEET
ROLL
6-7 Correcting Misalignment for Printing or Cutting
Press
.
Press
several times.
Press
.
Press
to start printing.
Choose the one that has the smallest gap
and the least amount of overlap.
Current correction value
Press
.
Press
.
Use
rection value.
Press
to enable the setting.
Press
.
Press
to go back to the original screen.
Overlap
to make the setting for the cor-
Chapter 6 Feature Reference