ATAPI Interface
Mode Tape Parameters Page
STT20000A Product Manual
Description
.Byte
18-19
Reserved
None of the Mode Capabilities and Mechanical Status Page (2Ah) parameters can
be changed.
Byte
Description
0
Page Code
Page Length
1
2
Density in Kilo bits per inch
3
Reserved
4
Reserved (Format Fill Byte)
5
BSEG
6,7
SEGTRK
8,9
TRKS
10
MAXSECT
11
MAXCYL
12
MAXHD
13,14
Reserved
15
WDAM,RM,FW (bits 7-5)
This page is used for MFM (Modified Frequency Modulation), or floppy interface
tape formats, such as 2080, 2120, TR1, TR2, TR3, etc. This feature is not available
in the STT20000A.
The following fields are changeable: SEGTRK, TRKS, MAXCYL, and MAXHD.
Value
Meaning
00h
—
Value
Meaning
2Bh
Tape Parameters Page
0Eh
14 Bytes of Information
NN
Density can imply tape format
00h
—
00h
Not used, MFM mode is read only
20h
Number of Blocks per Segment (32)
NNNN
Number of Segments per Track
NN
Number of Tracks (per Tape)
80h
Max MFM Sector Value (128)
NN
Max MFM Cylinder Value
NN
Max MFM Head Value
0000h
—
00h
Not Used, MFM mode is read only
Chapter 5
Page 53