Locate Command - Seagate STT20000A Product Manual

Atapi minicartridge drive
Table of Contents

Advertisement

ATAPI Interface

Locate command

Bit
7
Byte
0
1
2
3
(MSB)
4
5
6
7
8
9
STT20000A Product Manual
6
5
Reserved
If the Change Partition (CP) bit is set, the drive first changes to the specified
partition, then attempts to locate before the specified logical block. (All addresses
are interpreted as logical.) A locate to Block 0 (in any partition) is treated like a
rewind (to BOP)and does not start a read-ahead. Depending on the exact sequence
of commands, LOCATE to Block 0 might or might not report a Blank Check error.
The DSC bit is reset (0) after this command is accepted and is set (1) when
completed. REQUEST SENSE can then be used to verify successful command
completion.
4
3
Operation code (2Bh)
Reserved
Logical Block Address
Reserved
Partition
Reserved
Chapter 5
2
1
CP
Reserved
Page 43
0
(LSB)