DISASSEMBLY INSTRUCTIONS

<"Terminal with locking mechanism" Detaching points>
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
(1) Slide the sleeve and check if there is a locking lever or not.
Sleeve
Locking lever
9-1.
MU-A08ND
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws of the top panel.
(2) Remove the screws of the service panel.
(3) Remove the screw of the valve cover (MU-A08ND-
(4) Remove the screws of the cabinet.
(5) Remove the screws of the front panel and motor support.
(6) Remove the service panel, and remove the screw from
the inside.
(7) Remove the valve cover (MU-A08ND-
(8) Remove the top panel.
(9) Remove the cabinet.
Photo 3
Screws of the
service panel
Photo : MU-A08ND -
1Slide the sleeve.
2Pull the terminal while
pushing the locking
lever.
C2
).
C2
Screws of the
top panel
Service
panel
Screw
of the
valve
cover
C2
(2) The terminal with this connector has the locking
mechanism.
1Hold the sleeve, and
Connector
Photo 1
).
Screws
of the
cabinet
Photo : MU-A08ND -
Photo 2
17
pull out the terminal
slowly.
PHOTOS
Screws of the front panel
and motor support
Screws of the cabinet
C2
Screws of
the top panel
Screws of
the cabinet

Hide quick links: