11

DISASSEMBLY INSTRUCTIONS

<Detaching method of the terminal with locking mechanism>
The terminal which has the locking mechanism can be detached as shown below.
There are 2 types of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
(1) Slide the sleeve and check if there is a locking lever or not.
Sleeve
Locking lever
11-1. MSZ-HR25VF MSZ-HR35VF
MSZ-HR42VF MSZ-HR50VF
NOTE: Turn OFF the power supply before disassembly.
OPERATING PROCEDURE
1. Removing the panel
(1) Remove the screw caps on the panel and remove the
screws of the panel.
(2) Pull the panel slightly toward you, and then remove the
panel by pushing it upward.
OBH822H
(2) The terminal with this connector shown
Slide the sleeve.
Pull the terminal while
pushing the locking lever.
Photo 1
45
below has the locking mechanism.
Hold the sleeve, and
pull out the terminal slowly.
Connector
: Indicates the visible parts in the photos/figures.
: Indicates the invisible parts in the photos/figures.
PHOTOS/FIGURES
Front panel
Screws of the panel
Horizontal vane