Mitsubishi Electric MU-A08VD-P1 Service Manual
Mitsubishi Electric MU-A08VD-P1 Service Manual

Mitsubishi Electric MU-A08VD-P1 Service Manual

Split-type, air conditioner/ wireless type models
Hide thumbs Also See for MU-A08VD-P1:

Advertisement

SPLIT-TYPE, AIR CONDITIONERS

SERVICE MANUAL

Wireless type
Models
MU-A08VD-
MU-A10VD-
MU-A13VD-
NOTE:
• This service manual describes technical data of outdoor units.
• As for indoor units MS-A08VD -
P1
P1
P1
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················2
3. SPECIFICATION·················································3
4. OUTLINES AND DIMENSIONS ·························4
Indication of
model name
5. WIRING DIAGRAM ············································4
6. REFRIGERANT SYSTEM DIAGRAM ················5
MU-A08VD -
P1
7. PERFORMANCE CURVES ································6
MU-A10VD -
P1
8. TROUBLESHOOTING········································8
MU-A13VD -
P1
9. DISASSEMBLY INSTRUCTIONS·····················11
10. PARTS LIST······················································16
11. OPTIONAL PARTS ···········································18
,MS-A10VD -
and MS-A13VD -
P1
P1
, refer to the service manual OB396.
P1
No. OB397
TM

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MU-A08VD-P1

  • Page 1: Table Of Contents

    SPLIT-TYPE, AIR CONDITIONERS No. OB397 SERVICE MANUAL Wireless type Models MU-A08VD- MU-A10VD- MU-A13VD- CONTENTS 1. TECHNICAL CHANGES ····································2 2. PART NAMES AND FUNCTIONS······················2 3. SPECIFICATION·················································3 4. OUTLINES AND DIMENSIONS ·························4 Indication of model name 5. WIRING DIAGRAM ············································4 6. REFRIGERANT SYSTEM DIAGRAM ················5 MU-A08VD - 7.
  • Page 2: Technical Changes

    TECHNICAL CHANGES MU-07UV - MU-A08VD - 1. Outdoor unit model has been changed. •Dimension has been changed. (780Wo540Ho255D 800Wo550Ho285D) •Valve bed has been added. 2. Compressor has been changed. (RH135VGCC RH135VHCC) 3. Outdoor fan motor has been changed. (RA6V23-HA RA6V21-AC) 4.
  • Page 3: Specification

    SPECIFICATION Outdoor model MU-A13VD - MU-A08VD - MU-A10VD - Function Cooling Single phase Power supply 220-230-240V, 50Hz 3.7-3.7-3.7 Capacity 2.3-2.3-2.3 2.75-2.75-2.75 Dehumidification 1848-1872-1896 Air flow K /h 1740-1800-1860 Starting current 28-29.5-31 17-18-19 18-19-20 Compressor motor current 4.53-4.52-4.51 2.85-2.85-2.84 3.22-3.22-3.21 0.33-0.34-0.35 Fan motor current 0.24-0.25-0.25 3.36-3.36-3.36...
  • Page 4: Outlines And Dimensions

    OUTLINES AND DIMENSIONS Unit : mm OUTDOOR UNIT MU-A08VD - REQUIRED SPACE Basically open 100mm or more MU-A10VD - without any obstruction in front and on both sides of the unit. MU-A13VD - Drain hole [42 Air in Air in Open two sides of left, 2 holes 10X21 right, or rear side.
  • Page 5: Refrigerant System Diagram

    REFRIGERANT SYSTEM DIAGRAM Unit : mm MU-A08VD - MU-A10VD - OUTDOOR UNIT Refrigerant pipe (Option){9.52 Stop valve (with heat insulator) (with service port) Outdoor Flared heat connection exchanger Compressor Strainer #100 Flared connection Capillary tube Stop valve {3.0 x { 1.6 x 850 Refrigerant pipe (Option){6.35 (with heat insulator)
  • Page 6: Performance Curves

    MAX.REFRIGERANT PIPING LENGTH Refrigerant piping : m Piping size O.D : mm Model Max. length Max. height Liquid MU-A08VD - {9.52 MU-A10VD - {6.35 MU-A13VD - {12.7 MAX.HEIGHT DIFFERENCE Indoor unit w Max. Height Refrigerant Piping Max. Length Outdoor unit ADDITIONAL REFRIGERANT CHARGE(R22 : g) Refrigerant piping length (one way) Outdoor unit precharged...
  • Page 7: Indoor Unit

    How to measure the indoor air wet/dry-bulb temperature difference Attach at least 2 sets of wet and-dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air speed is high.
  • Page 8: Troubleshooting

    MU-A08VD - MU-A08VD - MU-A10VD - MU-A10VD - (kgf/F [Gauge])(MPa [Gauge]) 220V 220V 35(:) 35(:) Ambient temperature (˚C)/Ambient humidity (%) Ambient temperature (˚C)/Ambient humidity (%) MU-A13VD - MU-A13VD - (kgf/F [Gauge])(MPa [Gauge]) 220V 220V 35(:) 35(:) Ambient temperature (˚C)/Ambient humidity (%) Ambient temperature (˚C)/Ambient humidity (%) TROUBLESHOOTING MU-A08VD -...
  • Page 9 8-2. Instruction of troubleshooting Start Indoor unit Indoor unit OPERATION INDICATOR operates. doesn't receive lamp on the indoor unit is Outdoor unit the signal from flashing on and off. doesn't remote controller. operate. Outdoor unit Indoor unit Indoor unit doesn't Outdoor unit doesn't operate, operates, when...
  • Page 10 8-3. Trouble criterion of main parts MU-A08VD - MU-A10VD - MU-A13VD - Part name Check method and criterion Figure Measure the resistance between the terminals with a tester. Compressor (Coil wiring temperature -10°C ~ 40°C) (MC) Normal Color of INNER Abnormal lead wire PROTECTOR...
  • Page 11: Disassembly Instructions

    DISASSEMBLY INSTRUCTIONS <"Terminal with locking mechanism" Detaching points> The terminal which has the locking mechanism can be detached as shown below. There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism. The terminal without locking mechanism can be detached by pulling it out. Check the shape of the terminal before detaching.
  • Page 12 OPERATING PROCEDURE PHOTOS 2. Removing the electrical parts Photo 4 (1) Remove the service panel and the cabinet.(Refer to 1.) Compressor capacitor (C1) (2) Remove the following parts. •Compressor capacitor (C1) •Outdoor fan capacitor (C2) •Terminal block (TB) Outdoor fan capacitor (C2) Terminal block(TB) 3.
  • Page 13 OPERATING PROCEDURE PHOTOS 4. Removing the compressor Photo 6 Discharge pipe (1) Remove the cabinet. (Refer to 1.) (2) Remove the soundproof felt. Suction pipe (3) Remove the screws fixing the relay panel. (4) Remove the terminal cover. Glass (5) Pull out the lead wires from the glass terminal of the com- terminal pressor.
  • Page 14 9-2. MU-A13VD - OUTDOOR UNIT OPERATING PROCEDURE PHOTOS Photo 1 1. Removing the cabinet (1) Remove the screws fixing the top panel. (See Photo 2 and Screws of the front panel and motor support (2) Remove the top panel. (See Photo 3.) (3) Remove the screw fixing the service panel.
  • Page 15 OPERATING PROCEDURE PHOTOS 3. Removing propeller and the outdoor fan motor Photo 5 Outdoor fan motor lead wires (1) Remove the cabinet. (Refer to 1) Set screws of the (2) Remove the propeller nut and remove the propeller. outdoor fan motor NOTE : Loose the propeller in the rotating direction for Hook Relay panel...
  • Page 16: Parts List

    PARTS LIST MU-A08VD - MU-A10VD - MU-A13VD - 10-1. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTS This figure shows MU-A13VD.
  • Page 17 MU-A08VD - MU-A10VD - MU-A13VD - 10-1. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTS Part number that is circled is not shown in the illustration. Q'ty/unit Symbol Part No. Part Name Remarks in Wiring MU-A08VD- MU-A10VD- MU-A13VD- Diagram E02 899 232 CABINET E02 927 521...
  • Page 18: Optional Parts

    OPTIONAL PARTS        REFRIGERANT PIPES The air conditioner has flared connections its indoor and outdoor sides. Please use the optional extension pipe as follows. Additional Pipe size O.D mm (in.) refrigerant Model Part No. Pipe length Cross-section Insulation charge...
  • Page 20 HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO100-8310, JAPAN C C Copyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD. New publication, effective Mar. 2005 Distributed in Mar. 2005. No.OB397 106 Specifications subject to change without notice. Made in Japan...