Adjustment > Error Messages and Countermeasure

6-8 Error Messages and Countermeasure

A message may appear while you are adjusting the video camera. If a message appears, refer to the
following table and take appropriate corrective action.
Error Messages
CAN'T ADJUST WHITE BALANCE
PLEASE RETRY
PRESS ANY KEY
D RANGE OVER. ERROR ON da×
ADJUSTMENT
PRESS ANY KEY.
(×: Error code)
D RANGE OVER ERROR ON HALL AMP
IRIS CANNOT OPEN ANY MORE
PRESS ANY KEY
ERROR OCCURRED. IRIS TROUBLE
PRESS ANY KEY
ERROR OCCURRED ON da× ADJUSTMENT
PRESS ANY KEY
ERROR OCCURRED ON da0 and da1
ADJUSTMENT
PRESS ANY KEY
FILE NOT FOUND !!!!
PRESS ANY KEY
FILE OPEN ERROR !!!!
PRESS ANY KEY
ERROR OCCURRED ON C DUTY
ADJUSTMENT
PRESS ANY KEY
ERROR OCCURRED ON FDET
ADJUSTMENT
PRESS ANY KEY
ERROR OCCURRED. ZOOM DOES NOT
WORK
PRESS ANY KEY
STAURATION ERROR. TOO BRIGHT
PRESS ANY KEY
When adjusting the electric volume and adjustment
1) The subject is too bright or too dark.
2) Check the light box.
3) Move the camera closer to or away from the light box.
4) Supply power again and readjust.
1) Check the values in the hall amp circuit.
2) Defective soldering, damage to pattern, etc. in the above
circuit.
1) Supply power again and readjust.
2) The subject is too dark.
3) Check the light box.
4) Move the camera closer to the light box.
5) Check the values in the hall amp circuit.
6) Defective soldering, damage to pattern, etc. in the above
circuit.
1) Check whether or not power is supplied.
2) Check the values of the iris drive circuit.
3) Defective soldering, damage to pattern, etc. in the above
circuit.
4) Check the iris block and replace it if necessary.
1) Check the values in the hall amp circuit.
2) Defective soldering, damage to pattern, etc. in the above
circuit.
1) Check the values in the hall amp circuit and its peripheral
circuits.
2) Defective soldering, damage to pattern, etc. in the above
circuits.
1) The adjustment program (file) cannot be found.
2) Check the adjustment floppy disk and replace it if necessary.
1) The adjustment program (file) does not start.
2) Check the adjustment floppy disk and replace it if necessary.
1) Check the values of the iris drive circuit.
2) Defective soldering, damage to pattern, etc. in the above
circuit.
1) Supply power again and readjust.
2) Check the values in the hall amp circuit.
3) Defective soldering, damage to pattern, etc. in the above
circuit.
1) Supply power again and readjust.
1) The subject is too bright.
2) Move the camera further away from the light box.
6 - 14