Maintenance Of The Device; Operating Instructions - Parkside PLP 180 Manual

Kompernass soldering gun brochure
Table of Contents

Advertisement

www.kompernass.com +++ www.kompernass.com +++ www.kompernass.com +++

OPERATING INSTRUCTIONS

• Prior to use, draw the soldering tip through the soldering paste which is also supplied.
• Direct the soldering tip
• Actuate the push-button switch
• In order to heat up the soldering tip, keep the switch pressed down for max 12 sec. before
starting the soldering work until the necessary soldering heat has been reached - then let go
of the push-button switch.
Never operate the soldering gun for continuous peroids !
The duration of the power supply controls the soldering heat (longer power supply = higher
soldering heat). During the soldering process, never keep the push-button switch pressed down
for too long. Determine the necessary duration of the power supply in practice by checking the
soldering heat.
Press the ON/OFF switch
the gun for at least 48 seconds.
As soon as you let go of the push-button switch, the soldering heat is reduced automatically.
If the switch is actuated again, the heat increases rapidly. Constant soldering heat guarantees
an optimum soldering quality, melting of the soldering tip due to excessive temperatures is avoided
and the service life of the device is extended.
Prior to use, draw the soldering tip through the soldering paste which is also supplied.
Because the operating temperature is reached quickly, the device functions in a very energy-saving
manner. The special shape of the soldering-gun tip makes partial heating possible. Thus, the device
is particularly operator-friendly and accelerates the heating process in the case of tin soldering.

MAINTENANCE OF THE DEVICE

Soldering tips and the soldering gun housing are connected together using screws and nuts so
that the soldering tips can be quickly and easily changed.
Because the tip melts and wears after lengthy use, it is necessary to replace it at regular intervals.
CHANGING THE SOLDERING TIP
Unscrew and remove the two fixing screws connecting the tip and the housing. Replace the
old tip with a new one and re-insert and tighten the screws. The device is then ready for operation
once again.
towards the soldering point.
. The operation indicator
for a maximum of 12 seconds – then do not operate
5
lights up

Hide quick links: