Descaling The Machine - Jura ENA Micro 1 Instructions For Use Manual

Hide thumbs Also See for ENA Micro 1:
Table of Contents

Advertisement

Precondition: Your ENA is ready for use. The
Cleaning symbol L lights up.
L  T  Touch the Cleaning symbol for approxi-
mately 2 seconds.
The Coffee Grounds Container symbol ?
lights up.
T Empty the drip tray and coffee grounds
container and reinsert them.
The Cleaning symbol L lights up.
T Place a receptacle under the coffee spout.
L  T  Touch the Cleaning symbol.
The Y, <, > and L symbols flash, water
flows out of the coffee spout.
The operation is interrupted, the Ground
Coffee symbol v lights up.
T Open the powder chute for ground coffee
and drop in a JURA cleaning tablet.
T Close the powder chute for ground coffee.
The Cleaning symbol L lights up.
L  T  Touch the Cleaning symbol.
The Y, <, > and L symbols flash, water
flows out of the coffee spout several times.
The operation is interrupted, the Coffee
Grounds Container symbol ? lights up.
T Empty the drip tray and coffee grounds
container and reinsert them.
The Y, < and > symbols flash. The
machine heats up.
Your ENA is once more ready for use.
Cleaning the machine without a prompt: You can
initiate the 'Cleaning the machine' operation
manually at any time as long as the machine is
ready for use. Touch the ; and _ symbols at the
same time for approximately 2 seconds. The ;,
_, L and & or ! symbols light up brightly.
Continue with the first prompt (indicated by T) as
described in this section.

Descaling the machine

The ENA builds up deposits of limescale over time
and automatically prompts you to descale it when
necessary. The degree of calcification depends on
the hardness of your water.
J
WARNING
Non-recommended descaling agents (e.g. vinegar)
may contain substances that could damage the
machine or leave residues.
T  Use only original JURA descaling tablets.
These are specially formulated for your
machine.
J
WARNING
Harmful and irritating descaling agent. Harmful if
swallowed. Irritating to eyes and skin.
T  Keep children AWAY.
T  Avoid contact with skin and eyes.
T  Avoid generation of dust. Do not inhale dust.
T  After contact with skin, wash immediately
with plenty of water. In case of skin irritation,
seek medical advice.
T  After eye contact, immediately flush eyes
with plenty of water. Remove contact lenses.
Seek medical advice.
T  If swallowed, rinse mouth immediately and
drink large quantities of water. Do not
induce vomiting. Seek medical advice
immediately and show label.
NOTICE
If the descaling operation is interrupted, there may
be damage to the machine.
T  Allow the descaling program to run to the
end.
E The descaling program lasts approximately
40 minutes.
E JURA descaling tablets are available from
specialized dealers.
E If you use a CLEARYL Blue filter cartridge and
this is activated, you will not be prompted to
descale.
de
5 Maintenance
en
fr
it
en
es
pt
ru
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents