Ccb Connection Identification - State Water Heaters 120 Series Service Handbook

Commercial / residential gas water heaters
Hide thumbs Also See for 120 Series:
Table of Contents

Advertisement

ccb connection identification

J1 Socket - Transformer
pin #
1
120 VAC hot to transformer
2
not used
3
120 VAC neutral to transformer
4
24 VAC out from transformer
5
24 VAC out from transformer
J2 Socket - 120 VAC To Combustion Blower
pin #
1
120 VAC hot to Combustion Blower 3 pin socket, see Figure 7 on page 11
2
120 VAC neutral to Combustion Blower 3 pin socket, see Figure 7 on page 11
3
not used
4
not used
J3 Socket - 120 VAC Power Supply
pin #
1
120 VAC hot
2
Earth Ground
3
120 vAC neutral
J4 Male Spade Connector - Flame Sensor
J5 Socket - Igniter 120 VAC HSI (hot surface igniter)
pin #
1
120 VAC hot
2
120 vAC neutral
J6 Socket - 24 Volt Gas Valve, Pressure Switches, Enable/Disable Circuit
pin #
1
not used
2
Gas valve - 24 VAC output (rectified to 24 VdC at the gas valve wiring harness plug end)
3
not used
4
Blocked Intake Air switch
5
Blocked Exhaust switch
6
Blower Prover switch
7
Blower Prover switch
8
Enable/disable external control circuit - jumper installed from factory
9
not used
10
Blocked Exhaust switch
11
Enable/disable external control circuit - jumper installed from factory
12
not used
13
not used
14
Blocked Intake Air switch
15
Gas valve - 24 VAC output (rectified to 24 VdC at the gas valve wiring harness plug end)
42
Servicing should only be performed by a Qualified Service Agent