Error Display - Intelligent Weighing Technology QHD+3 Service Manual

Counting scale qhd series
Table of Contents

Advertisement

9. ERROR DISPLAY

Error Message
-----
Maximum load exceeded Unload or reduce weight
Incorrect date
Err 1
Err 2
Incorrect time
Err 4
Zero setting error
Err 5
Key board error
Err 6
A/D value out of range
Err 9
Unstable Reading
Err 17
Tare out of range
--ol--
Over range
Calibration Error
Fai l h /
fai l l
Err p
Printer error
Battery low
Ba lo /
lo ba
- 24 -
Description
Solution
Enter the date by using format
"yy;mm:dd"
Enter the time by using format
"hh:mm:ss"
Zero setting range exceeded due
to switching on.(4%max)
Make sure platform empty.
Check the keys and connecter.
Make sure platform empty and
check the pan is installed proper.
Check the load cell connectors.
Check any air variation, vibration,
RF noise and touching some
where.
Check the load cell and
connecters.
Remove the load and restart scale
again.
Remove the load.
Re calibrate
Re calibrate
Check the printer and settings
Re charge battery, check the
voltages.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QHD+3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Qhd+6Qhd+15Qhd+30

Table of Contents