Toshiba e-STUDIO161 Service Manual page 92

Multifunction digital system
Hide thumbs Also See for e-STUDIO161:
Table of Contents

Advertisement

(5) Attach the copier to the paper tray unit.
*Remove the paper tray before attaching the copier.
Place the copier on the second paper tray unit and secure four fixing
plates A using the eight screws (P Tite M4).
(6) Remove the connection gear lock.
After attaching the copier, pull the red tag out in the direction of the
arrow and remove the connection gear lock.
(7) Connect the connector.
Connect the optional relay harness contained in the second paper tray
unit to the PWB of the copier.
• Optional relay harness
MY-1022 OPTION MY-1022 (250 sheets paper feed unit)
(8) Reattach the cover of the paper tray unit.
Reattach the rear cover to its original position and secure it with the two
screws (S Tite M4).
(9) Reattach the rear cabinet of the copier.
Reattach the rear cabinet to its original position and secure it with the
five screws (three M3 x 6 screws, one M3 x 8 screw, and one P Tite M4
screw).
Then attach the cover and secure it with the screw (M3 x 8).
(10) Reattach the document cover.
Insert the hinge portions of the document cover into the mounting por-
tions of the copier by holding the cover at an angle toward the rear side.
(11) Remove the fixture for packing the paper tray.
Rotate the fixture for packing that secures the paper pressure plate in
the paper tray in the direction of the arrow to remove it.