6. ADJUSTMENTS

A. Auto white correction pixel adjustment
[Function]
The white correction start pixel position is automatically adjusted.
This adjustment is performed after the lens unit is replaced.
[Operation]
Open the ADF unit and press the [OK] key.
7-segment indicates the order number of the pixel of the white sheet for ADF exposure
correction in the ADF position.
It will display on 7-segment, if values are 93-299, and data are written into the EEPROM.
It will display on 7-segment, it values are 0-92 or 230-999, and data are not written into
the EEPROM.
It will display "--" on 7-segment, it values is 1000 or larger, and data are not written into
the EEPROM..
[CA] key: Cancels the test command.
[Interruption] key: Shifts to the sub code entry menu.
The ADF white correction start pixel = Displayed pixel position - 34
Interruption is inhibited during execution.
If the simulation is executed with the ADF unit closed, an error is resulted.
During execution,"EXEC" is highlighted
B. Magnification ratio adjustment
Note: • When performing this adjustment, check that the CCD unit is
properly installed.
• When performing this adjustment, check that the OC mode
adjustment in copying is completed.
1) Place a scale on the document table as shown below, and make a
normal copy to make a test chart.
Note: Since the printed paper is used as the test chart,
place the scale in parallel to both sides.
2) Set the test chart to the ADF and make a normal copy.
3) Compare the copy and the test chart.
If an adjustment is needed, perform the following procedures.
4) Execute SIM 48-5.
5) The current correction value is displayed on the display section in
two digits.
6) Enter the set value, and press the START key.
The entered correction value is stored and a copy is made.
7) Change the TEXT mode.
The TEXT lamp lights up, and the current correction value of the
back surface sub scanning direction magnification ratio is displayed
on the display section in two digits.
8) Enter the set value, and press the START key.
The entered correction value is stored and a copy is made.
<Adjustment specifications>
Mode
Spec
Magnification
Normal:
SIM 48-5
m 1.0%
ratio adjustment
AE: Surface
TEXT: Back
MR-2015 OPTION MR-2015 (ADF)
Set
SIM
Set value
range
Add 1:
1 ~ 99
0.1% increase
Reduce 1:
0.1% decrease
C. Document off center adjustment
Note: When performing this adjustment, check that the paper off-cen-
ter is properly adjusted.
1) Set the center position adjustment test chart (made by yourself) on
the ADF.
<Adjustment specifications>
Draw a line in the center of paper. (In the scanning direction)
2) Make a normal copy from the manual feed tray, and compare the
copy and the test chart.
If an adjustment is required, perform the following procedures.
3) Execute SIM 50-12.
4) The current off-center adjustment value is displayed on the display
section in two digits.
5) Enter the set value and press the START key.
The entered correction value is started and a copy is made.
<Adjustment specifications>
Mode
Specification
Document
Simplex:
Center m 3.0mm
off-center
Duplex:
Center m 3.5mm
D. Image lead edge position adjustment
1) Set a scale on the OC table as shown below.
Note: Since the printed paper is used as the test chart,
place the scale in parallel to both sides.
2) Make a copy, and use the copied paper as the document and make
a copy from ADF again.
3) Check the copied paper. If an adjustment is required, perform the
following procedures.
4) Execute SIM 50-6.
5) Set the ADF lead edge position set value so that the image similar
to the adjusted image at the OC image lead edge position
described previously is printed.
<Adjustment specifications>
Adjustment
SIM
mode
Image
SIM 50-6 1step: 0.1mm shift Lead edge void:
lead edge
position
15 – 7
SIM
Set value
AE: Surface
Add 1:
0.1mm shifted to
TEXT: Back
R side.
Reduce 1:
0.1mm shifted to L
side.
Set value
Specification
1 ~ 4mm
Image loss:
3mm or less
Set
range
1 ~ 99
Set
range
1 ~ 99