KERN MFB 150K100 Version 1.0 08/2008 Operating Manual Body fat balance Table of Contents Technical Data__________________________________________________ 3 Basic Information (General)_______________________________________ 4 Proper use _______________________________________________________ 4 Improper Use ____________________________________________________ 4 Warranty ________________________________________________________ 5 Basic Safety Precautions _________________________________________ 5 Pay attention to the instructions in the Operation Manual________________ 5 Transportation &...
1 Technical Data KERN MFB 150K100 Readability (d) 100 g Weighing range (max) 150 kg Weighing Units kg, lb Reproducibility +- (100 g +1%) Linearity +- (100 g +1%) Stabilization time (typical) 2 – 3 sec. Battery operated 4 x 1.5V, size AAA...
The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. MFB -BA-e-0810...
3 Basic Safety Precautions 3.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances. 4 Transportation & Storage 4.1 Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.
4 alkaline batteries of AAA size in the correct direction of the pole, then close the battery compartment. If the balance is not used for a longer time, take out the batteries and store them separately. Leaking battery liquid could damage the balance. MFB -BA-e-0810...
6.1.2 Keys and display overview Display Description Selecting parameters [arrow down] ▼ Selecting or confirming your selection [SET] Selecting parameters [arrow up] Default: Gender of person Male Female Default: Age of person Default: Height of person Display: Body fat ratio in % MFB -BA-e-0810...
"male“ and “female“ by pressing the arrow keys. Confirm by pressing SET. c. When body height ( cm ) starts to flash, you can change this value, too, by pressing the arrow keys. Again, confirm by pressing SET. MFB -BA-e-0810...
After the weighing value has come to a stop, the symbol “o“ will drift across the display indicating that weighing is taking place. c. After successful completion of the weighing process, the body fat ratio will be shown in percent. ( fat ) MFB -BA-e-0810...
Page 10
6. The display will switch over once again in order to show the absolute weight of the bones in the body. ( BONE ) The 4 display values described above will run through twice in succession. Finally the balance will switch off. MFB -BA-e-0810...
Page 11
Male: normal : > 40 % Bone (kg): Female Male Body weight < 45 kg 45-60 kg > 60 kg < 45 kg 45-60 kg > 60 kg Estimated bone 1.8 kg 2.2 kg 2.5 kg 2.5 kg 2.9 kg 3.2 kg weight MFB -BA-e-0810...
The appliance may only be opened by trained service technicians who are authorized by KERN. 9.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. MFB -BA-e-0810...
• Great fluctuations in temperature. • Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. MFB -BA-e-0810...