  • Page 1 KERN & Sohn GmbH Ziegelei 1 Phone: +49-[0]7433- 9933-0 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@kern-sohn.com Internet: www.kern-sohn.com Operating manual Electronic bathroom scales KERN MPI Version 1.0 2017-07 MPI-BA-e-1710...
  • Page 2: Table Of Contents

    KERN MPI Version 1.0 2017-07 Operating manual Bathroom Balance Contents Technical data ....................3 Declaration of conformity ................. 4 Basic Information (General) ................4 Proper use ........................ 4 Improper Use......................4 Warranty ........................4 Basic Safety Precautions .................. 5 Pay attention to the instructions in the Operation Manual ........5 Transport and storage ..................
  • Page 3: Technical Data

    1 Technical data KERN MPI 200K-1 Readability (d) 0.1 kg Weighing range (max) 200 kg Accuracy +- 0.5% +- 0.1kg Weighing Units kg, lb Warm-up time 10 min. Operating temperature -10° C …. + 40° C Height of digits (mm) Humidity of air max.
  • Page 4: Declaration Of Conformity

    The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 3.3 Warranty Warranty claims shall be voided in case ...
  • Page 5: Basic Safety Precautions

    Stepping on the edge of the weighing plate may cause tilting of balance or fall of person.  Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances. 5 Transport and storage 5.1 Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.
  • Page 6: Unpacking

    The occurrence of electric fields or electrostatic charge may result in major display deviations (incorrect weighing results). In that case, the location must be changed. 6.2 Unpacking Take the whole balance out of their packaging and place them at the intended position.
  • Page 7: Using The Balance

    8 Using the balance  The weighing process requires that the person stands on the weighing plate in a way that provides even weight distribution over the entire weighing plate.  Remain as upright and still as possible during the weighing process. ...
  • Page 8: Servicing, Maintenance, Disposal

    Remove dirt immediately. 9.2 Servicing, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. 9.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used.
  • Page 9: Instant Help

    11 Instant help Help: Fault Possible cause The displayed weight is • Draught/air movement permanently changing • Table/floor vibrations • Weighing plate has contact with other objects • Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) The weighing result is •...