Throttle Position Sensor (Tps) - Arctic Cat 08 ATV Service Manual

Table of Contents

Advertisement

FOR ARCTIC CAT ATV DISCOUNT PARTS CALL 606-678-9623 OR 606-561-4983
2. Install the needle adapters to the multimeter leads;
then select DC Voltage on the multimeter.
3. Connect the red tester lead to the blue/brown wire
(B) and the black tester lead to the black/yellow
wire (A); then turn the ignition switch ON and
observe the meter. The meter should read 0.8-3.0
DC volts.
4. Tilt the sensor 60° or more to the left and right
observing the meter. The meter should read 3-7
DC volts after approximately one second in the
tilted position. If the meter readings are not as
specified, the tilt sensor is defective.
NOTE: When replacing the sensor after testing,
make sure the arrow marking is directed up.
www.mymowerparts.com
Back
5-16
CD707
CD705B
CD709
Back to TOC
Throttle Position
Sensor (TPS)
INSPECTING
1. Remove the right-side engine cover; then discon-
nect the three-wire TPS connector plug.
NOTE: Prior to testing the TPS, inspect the
three-wire plug connector on the main harness
and the three-pin plug on the TPS for contamina-
tion, broken pins, and/or corrosion.
2. Make sure the ignition switch is in the OFF posi-
tion; then select the DC Voltage position on the
meter.
3. Connect the black tester lead to spade terminal C
and the red tester lead to spade terminal B. Turn
the ignition switch to the ON position. The meter
should read 4.5-5.5 DC volts.
Back to Section TOC