Table 6: Alarm Interface Port Pinouts

Pin
Name
1
CRIT_ALARM_COM
2
CRIT_ALARM_NO
3
MJR_ALARM_NC
4
+24 VDC source 100 mA
referenced to chassis
ground
5
ALARM_IN4_EXT_+
6
ALARM_IN3_EXT_+
7
ALARM_IN2_EXT_+
8
ALARM_IN1_EXT_+
9
CRIT_ALARM_NC
10
MJR_ALARM_COM
11
MJR_ALARM_NO
12
ALARM_IN4_EXT_RTN

Appendix C: Alarm Pin Assignments

Function
Common contact for Critical alarm relay.
Normally open contact will be connected to
the common contact during a Critical alarm
state.
Normally closed contact will be disconnected
from the common contact during a Major
alarm state.
Available as a source voltage for use with
Alarm In 1-4.
External alarm input 4 (external relay dry
contact closure to pin 12).
External alarm input 3 (external relay dry
contact closure to pin 13).
External alarm input 2 (external relay dry
contact closure to pin 14).
External alarm input 1 (external relay dry
contact closure to pin 15).
Normally closed contact will be disconnected
from the common contact during a Critical
alarm state.
Common contact for Major alarm relay.
Normally open contact will be connected to
the common contact during a Major alarm
state.
External alarm input 4 (external relay dry
contact closure from pin 5).