Alcatel-Lucent 7210 SAS-T Installation Manual page 101

Service access switch
Hide thumbs Also See for 7210 SAS-T:
Table of Contents

Advertisement

7210 SAS-T Installation Guide
name "M3"
alarm-contact-input
exit
alarm-contact-input 2
exit
alarm-contact-input 3
exit
alarm-contact-input 4
exit
*A:M3>config>system# show alarm-contact-input all
=====================================================================
Alarm Contact Input
=====================================================================
Alarm Input Pin Number : 1
Alarm Input Pin Description : Door ALARM SENSOR
Alarm Input Pin Current State : no-alarm
Alarm Output Pin Used : Major
Last State Change : 02/21/2011 16:02:02
Alarm Input Pin Number : 2
Alarm Input Pin Description : Chassis SENSOR
Alarm Input Pin Current State : alarm
Alarm Output Pin Used : Critical
Last State Change : 02/21/2011 12:36:22
Alarm Input Pin Number : 3
Alarm Input Pin Description :
Alarm Input Pin Current State : Disabled
Alarm Output Pin Used : Major
Last State Change : 01/24/2011 12:55:51
Alarm Input Pin Number : 4
Alarm Input Pin Description :
Alarm Input Pin Current State : Disabled
Alarm Output Pin Used : Major
Last State Change : 01/24/2011 12:55:51
Appendix C: Alarm Pin Assignments
description "Door ALARM SENSOR"
trigger-alarm-msg "Somebody opened door"
clear-alarm-msg "Door SENSOR ALARM cleared"
no shutdown
description "Chassis SENSOR"
alarm-output-severity Critical << Mandatory CLI
normal-state closed
trigger-alarm-msg "Somebody opened CHASSIS"
clear-alarm-msg "CHASSIS open ALARM CLEARED"
no shutdown << Mandatory CLI
shutdown
shutdown
Page 93

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents