HP JG221A Installation Manual page 55

A3100 v2 switch series
Table of Contents

Advertisement

Type
Category 5e
Category 6
Based on pinouts
Ethernet twisted pair cables can be classified into straight through and crossover cables based on their
pinouts.
Straight-through: The pinouts at both ends comply with standard 568B. See
Crossover: The pinouts at one end comply with standard 568B, and those at the other end comply with
standard 568A. See
Figure 47 Straight-through cable
Straight-through cable
Description
Suitable for data transmission at a maximum speed of 1000 Mbps, with a
bandwidth of 100 MHz.
Suitable for data transmission at a speed higher than 1 Gbps, with a bandwidth of
250 MHz.
Figure
48.
white/orange
1
2
white/green
3
4
5
white/blue
6
7
white/brown
8
1
white/orange
2
white/green
3
4
5
white/blue
6
white/brown
7
8