2mp tvi 940nm black ir led motorized zoom focus camera (32 pages)
Summary of Contents for Speco HTSD12X
Page 1
HTSD12X 12X Optical Zoom Indoor / Outdoor Speed Dome Camera Please read this manual thoroughly before operation and keep it handy for further reference.
CONTENTS CONTENTS CONTENTS CONTENTS Warning & Caution What’s in the Box? General Features Overview of Parts Installation A. Connection Methods B. Ceiling Mount Type C. Embedded Mount Type Quick Operation Keys Diagnostic OSD Menu Setting A. OSD Menu Table B. DOME SET C.
WARNING WARNING WARNING WARNING & & & & CAUTION CAUTION CAUTION CAUTION If you fail to read this information and handle the product incorrectly, death or serious injury may occur. The unit should be installed by a trained professional Immediately stop usage when the product emits smoke or abnormal heat.
GENERAL FEATURES GENERAL FEATURES GENERAL FEATURES GENERAL FEATURES 144X Zoom Mini Speed Dome Quick Operation Keys 12X Optical Zoom with 12X digital zoom This camera provides quick functional keys to be easily controllable by another controller or DVR. 0 .02 dome system accuracy with 1/4 ±...
OVERVIEW OF PARTS OVERVIEW OF PARTS OVERVIEW OF PARTS OVERVIEW OF PARTS 1. Surface Mount Adaptor 2. Cap Screw ( PT3/4 , 2EA ) 3. Dip Switch 4. Terminal Block 5. Main body...
INSTALLATION INSTALLATION INSTALLATION INSTALLATION A. CONNECTION METHOD Loosen the screws on the dome cover and remove it from the base. (Screws will not fall out) Loosen the screws which connect mount cover and Main base and separate dome cover from the main base.
INSTALLATION INSTALLATION INSTALLATION INSTALLATION B. MOUNT 1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to install. (FIG.4) 2. When you use pipe, please note the standard size of pipe. (FIG.5) 3. Re-assemble the domes.
Q Q Q Q UICK OPERAT UICK OPERATION ION KEYS KEYS UICK OPERAT UICK OPERAT KEYS KEYS 1-64 + preset and 101~200 + preset are used for preset and 65-100 + preset used for functions. For example, to enter OSD MENU, press the button 95 +PRESET or 95 +ENTER <Quick Operation Key Table 1, Pelco - D, P>...
Q Q Q Q UICK OPERAT UICK OPERATION ION KEYS KEYS UICK OPERAT UICK OPERAT KEYS KEYS DIAGNOSTIC DIAGNOSTIC DIAGNOSTIC DIAGNOSTIC When Power is on, DIAGONOSTIC is operational. The following messages are displayed on the monitor. CAMERA ID : 001 BAUD RATE : 2400 BPS WAITING………...
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING To enter OSD Menu, press the button 95 + PRESET. MAIN MENU DOME SETUP PRESET CAMERA SET AUTO SCAN TOUR PRIVACY...
Page 12
OS D M OS D MENU S ETTING ENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING B-2. DOME SET - RECOVER This feature allows the dome to recover to the last setting before the dome was used manually (Auto scan, group tour, pattern or sectors), after the set time, power will shut down and turn back Recover time can be programmed from 15 second to 90 seconds.
Page 13
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING B-8-2. DOME SET – [NEXT PAGE] – [PASSWORD] To enter this page to set a password, SYSTEM LOCK should be ‘ON’ then move joystick to the right direction on [PASSWORD].
Page 14
OS D MENU S ETTING OS D M ENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING OSD DISPLAY CAMERA ID : OFF DEFAULT SETTING PRESET ID : OFF SECTOR ID : OFF COORDINATE : ON [PREVIOUS PAGE] B-8-4.
Page 15
OS D MENU S ETTING OS D M ENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING - To clear any stored setting, move joystick to the right direction when cursor is on each item.
OS D M OS D M OS D M OS D MENU S ETTING ENU S ETTING ENU S ETTING ENU S ETTING C. CAMERA SET CAMERA SET FLICKER : OFF MIRROR : OFF APERTURE : 02 D ZOOM : OFF WB MODE : ATW2 MODE PIC FLIP...
Page 17
OS D M OS D MENU S ETTING ENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING C-6. CAMERA SET – PIC FLIP Flips the picture horizontally. Move joystick to the right or left direction to select OFF/ON. The default setting is OFF.
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING D. PRESET SET To enter PRESET SET, move joystick to the right direction. PRESET SET PRESET NO :001 PRESET ID :PRESET001------- PAN :XXX.XX TILT : XXX.XX SAVE...
OS D MENU S ETTING OS D M ENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING E. AUTO SCAN SET * 66 + preset button is working as AUTO SCAN after setting. AUTO SCAN SET START ANGLE : XXX.X.XX.X END ANGLE...
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING F. TOUR SET 8 Programmable tours can be set and each tour is available to set up to 60 preset steps. After setting the data to the each tour group, 71~78 + preset buttons are working as group tour # 1~8 TOUR SET TOUR NO...
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING G. PRIVACY SET 4 Privacy masking zones are available to block out areas of security. PRIVACY SET PRIVACY NUMBER : 01 DISPLAY : OFF...
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING H. PATTERN SET 8 programmable patterns are available with 16 characters of title. After setting the data to each pattern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8. PATTERN SET PATT NO : 01...
OS D M OS D MENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING ENU S ETTING I. ALARM SET 4 Alarm inputs are available and each alarm is activating to presets, group tours or patterns. ALARM SET ALARM NO : 01...
OS D MENU S ETTING OS D M ENU S ETTING OS D M OS D M ENU S ETTING ENU S ETTING J. SECTOR SET Up to 8 programmable sectors are available with 16 characters. This feature is useful to store certain locations such as parking zone, etc. When the camera scans this area, it shows the stored value.
DIP SWITCH SETTING DIP SWITCH SETTING DIP SWITCH SETTING DIP SWITCH SETTING A-1. DIP SW SETTING Mini Speed Dome camera provides up to 63 camera ID and it’s an adjustable ID with 1 of Dip switch. Open the camera case to set ID using DIP SW1. * Factory default: Camera ID = 1, PELCO-D Termination Baud rate...
TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING If you have trouble in operating in your camera, refer to the following. PROBLEM SOLUTION Check if the power supply is DC12V or AC24V. Check if RS-485 communication cable is connected correctly. No operation Check camera ID setting. Check the termination.
Page 32
Speco Technologies is constantly developing product improvements. We reserve the right to modify product design and specifications without notice and without incurring any obligation. (Rev. 130328)
Need help?
Do you have a question about the HTSD12X and is the answer not in the manual?
Questions and answers