F a u l t c o d e d i s p l a y
The B 500 Professional has an independent monitoring system that gives you the possibility of spotting
errors quickly and reacting accordingly.
The fault display can be combined with an acoustic signal so that a "beep" can be heard in addition to the
display being shown. You can select this setting yourself. Please refer to the section on "Menu program-
ming".
The following fault codes tell you what problem has occurred and what has to be done.
Note: If a fault code is displayed, only the On/Off button and the PROG and SET key on the remote control
unit can be used.
fault code
fault
01
Water tank is empty
02
UV lamp defective
03
Water leaking
(only possible with external water sensor)
04
Water tank overfilled
(only possible with automatic water supply)
05
No radio signal from hygrostat. The receiver on the control
panel has not received a signal for a quite some time.
09
Several faults have occurred simultaneously
8
Disconnect the mains plug before opening the equipment!
What to do?
- Check water level and top up if
necessary
- Check water level diodes for dirt and
clean if necessary.
- Has distilled water been used? If so, top
up with plain tap water.
- Check the diodes connection.
- Is the automatic water supply defective?
(optional extra)
- Replace UV lamp
(see "Changing the UV tube")
- Check whether the filter has been
inserted correctly.
- Check whether the appliance
is standing upright.
- Check whether the automatic water
supply is working correctly (if fitted)
- Check tank for leaks
- Check the function of the magnetic valve
- Check the water level diodes for dirt.
- Is the radio transmitter too far away
from the appliance?
- Check the function and coding of the
radio transmitter (see "Starting up" /
"Coding the radio sensor system").
- Replace battery if necessary
Check the appliance as described
for Faults 01 to 04.